Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,115
matching recommendationsSIC | 349 | Misc. Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0468 # 01 Y:2004 | 01 | 2004 | OPTIMIZE PLANT POWER FACTOR | $3,870 | $14,200 | n/a |
AM0468 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,520 | $800 | Implemented |
AM0468 # 03 Y:2004 | 03 | 2004 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,510 | $760 | Implemented |
AM0468 # 04 Y:2004 | 04 | 2004 | OPTIMIZE PLANT POWER FACTOR | $1,100 | $4,590 | Not Implemented |
AM0468 # 05 Y:2004 | 05 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $270 | $110 | Implemented |
AM0468 # 06 Y:2004 | 06 | 2004 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $37,000 | $0 | Implemented |
AM0468 # 07 Y:2004 | 07 | 2004 | PAY UTILITY BILLS ON TIME | $390 | $0 | Implemented |
OK0686 # 01 Y:2004 | 01 | 2004 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $13,360 | $160 | Not Implemented |
OK0686 # 02 Y:2004 | 02 | 2004 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $1,472 | $262 | Implemented |
OK0686 # 03 Y:2004 | 03 | 2004 | INSTALL OCCUPANCY SENSORS | $3,350 | $1,136 | Implemented |
OK0686 # 04 Y:2004 | 04 | 2004 | INSTALL SET-BACK TIMERS | $1,577 | $1,320 | Implemented |
OK0686 # 05 Y:2004 | 05 | 2004 | UTILIZE A CENTRAL COOLANT SYSTEM FOR CLEANING AND REUSE OF METAL WORKING FLUID | $70,533 | $81,950 | Not Implemented |
OK0686 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,153 | $36,618 | Implemented |
OK0686 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $537 | $2,550 | Implemented |
OK0686 # 08 Y:2004 | 08 | 2004 | USE OPTIMUM THICKNESS INSULATION | $8,220 | $40,318 | Not Implemented |
OK0686 # 09 Y:2004 | 09 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,706 | $22,116 | Not Implemented |
AM0461 # 01 Y:2004 | 01 | 2004 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $71,800 | $17,950 | Implemented |
AM0461 # 02 Y:2004 | 02 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $24,000 | $1,920 | Implemented |
AM0461 # 03 Y:2004 | 03 | 2004 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $12,560 | $5,000 | Not Implemented |
AM0461 # 04 Y:2004 | 04 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,630 | $20 | Implemented |
AM0461 # 05 Y:2004 | 05 | 2004 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $3,730 | $0 | Implemented |
AM0461 # 06 Y:2004 | 06 | 2004 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $3,480 | $0 | Implemented |
AM0461 # 07 Y:2004 | 07 | 2004 | INSULATE BARE EQUIPMENT | $3,430 | $900 | Implemented |
AM0461 # 08 Y:2004 | 08 | 2004 | INSTALL SKYLIGHTS | $2,600 | $6,200 | Implemented |
AM0461 # 09 Y:2004 | 09 | 2004 | INSTALL SKYLIGHTS | $2,230 | $5,400 | Not Implemented |