Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
132
matching recommendationsSIC | 349 | Misc. Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0890 # 04 Y:2014 | 04 | 2014 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,200 | $0 | Implemented |
OK0890 # 05 Y:2014 | 05 | 2014 | AIR CONDITION ONLY SPACE NECESSARY | $6,400 | $1,230 | Implemented |
OK0890 # 01 Y:2014 | 01 | 2014 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $9,580 | $770 | Not Implemented |
OK0890 # 02 Y:2014 | 02 | 2014 | INSTALL COMMON HEADER ON COMPRESSORS | $8,687 | $4,800 | Implemented |
OK0890 # 07 Y:2014 | 07 | 2014 | USE MINIMUM SAFE OVEN VENTILATION | $30,394 | $1,000 | Implemented |
OK0890 # 03 Y:2014 | 03 | 2014 | INSTALL COMMON HEADER ON COMPRESSORS | $1,460 | $1,200 | Not Implemented |
OK0890 # 06 Y:2014 | 06 | 2014 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,700 | $0 | Implemented |
OK0851 # 01 Y:2013 | 01 | 2013 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $3,442 | $0 | Not Implemented |
OK0851 # 02 Y:2013 | 02 | 2013 | OPTIMIZE PLANT POWER FACTOR | $6,232 | $14,940 | Not Implemented |
OK0851 # 03 Y:2013 | 03 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,912 | $6,000 | Not Implemented |
OK0851 # 05 Y:2013 | 05 | 2013 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $7,400 | $44,200 | Implemented |
OK0851 # 04 Y:2013 | 04 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $647 | $1,132 | Not Implemented |
OK0851 # 06 Y:2013 | 06 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,400 | $1,900 | Implemented |
OK0844 # 04 Y:2013 | 04 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,154 | $4,200 | Implemented |
OK0844 # 05 Y:2013 | 05 | 2013 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $6,800 | $18,500 | Not Implemented |
OK0844 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,922 | $21,000 | Implemented |
OK0844 # 03 Y:2013 | 03 | 2013 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $11,299 | $76,750 | Implemented |
OK0844 # 02 Y:2013 | 02 | 2013 | OPTIMIZE PLANT POWER FACTOR | $6,000 | $32,130 | Not Implemented |
TT0063 # 01 Y:2011 | 01 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $339 | $0 | Not Implemented |
TT0063 # 05 Y:2011 | 05 | 2011 | DEVELOP A REPAIR/REPLACE POLICY | $8,057 | $30,500 | Not Implemented |
TT0063 # 02 Y:2011 | 02 | 2011 | REPAIR OR REPLACE STEAM TRAPS | $6,712 | $4,800 | Not Implemented |
TT0063 # 04 Y:2011 | 04 | 2011 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $900 | $1,050 | Implemented |
TT0063 # 03 Y:2011 | 03 | 2011 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $1,238 | $0 | Not Implemented |
TT0063 # 07 Y:2011 | 07 | 2011 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $2,424 | $120 | Not Implemented |
TT0063 # 06 Y:2011 | 06 | 2011 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $12,516 | $4,000 | Not Implemented |