Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

661

matching recommendations
Reset
SIC 3496 Misc. Fabricated Wire Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0580 # 09 Y:1999 09 1999 SWITCH TO A SOLVENT THAT CAN BE CLEANED AND RE-USED $1,418 $0 Not Implemented
DS0145 # 01 Y:1999 01 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,985 $8 Implemented
DS0145 # 02 Y:1999 02 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,434 $462 Implemented
DS0145 # 03 Y:1999 03 1999 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $15,332 $945 Not Implemented
MA0440 # 01 Y:1999 01 1999 CHANGE OPERATING CONDITIONS $29,415 $130,900 Not Implemented
MA0440 # 02 Y:1999 02 1999 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,896 $15,790 Implemented
MA0440 # 03 Y:1999 03 1999 CHANGE OPERATING CONDITIONS $2,562 $27,140 Not Implemented
MA0440 # 04 Y:1999 04 1999 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,444 $3,400 Implemented
MA0440 # 05 Y:1999 05 1999 RECOVER WASTE HEAT FROM EQUIPMENT $3,278 $5,204 Implemented
MA0440 # 06 Y:1999 06 1999 RECOVER WASTE HEAT FROM EQUIPMENT $12,349 $70,000 Not Implemented
MA0440 # 07 Y:1999 07 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $709 $1,245 Implemented
MA0440 # 08 Y:1999 08 1999 MINIMIZE WATER USAGE $6,136 $10,000 Not Implemented
AM0336 # 01 Y:1999 01 1999 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $84,980 $80,500 Implemented
AM0336 # 02 Y:1999 02 1999 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $3,750 $0 Implemented
AM0336 # 03 Y:1999 03 1999 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $640 $800 Not Implemented
AM0336 # 04 Y:1999 04 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $600 $100 Implemented
AM0336 # 05 Y:1999 05 1999 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $460 $0 Not Implemented
AM0336 # 06 Y:1999 06 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $290 $14 Not Implemented
AM0336 # 07 Y:1999 07 1999 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $135 $0 Not Implemented
AM0335 # 01 Y:1998 01 1998 OPTIMIZE LOT SIZES TO REDUCE INVENTORY CARRYING COSTS $19,840 $320 Not Implemented
AM0335 # 02 Y:1998 02 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,790 $250 Implemented
AM0335 # 03 Y:1998 03 1998 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $2,025 $1,015 Implemented
AM0335 # 04 Y:1998 04 1998 OPTIMIZE PLANT POWER FACTOR $930 $2,585 Not Implemented
AM0335 # 05 Y:1998 05 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,050 $100 Implemented
AM0335 # 06 Y:1998 06 1998 OPTIMIZE PLANT POWER FACTOR $525 $1,525 Not Implemented