Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
661
matching recommendationsSIC | 3496 | Misc. Fabricated Wire Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0013 # 07 Y:1991 | 07 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,089 | $1,892 | Implemented |
UF0013 # 08 Y:1991 | 08 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,841 | $3,067 | Implemented |
UF0013 # 09 Y:1991 | 09 | 1991 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $756 | $880 | Implemented |
UF0013 # 10 Y:1991 | 10 | 1991 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,713 | $20,700 | Implemented |
TN0435 # 01 Y:1991 | 01 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,971 | $6,000 | Implemented |
TN0435 # 02 Y:1991 | 02 | 1991 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,926 | $0 | Implemented |
TN0435 # 03 Y:1991 | 03 | 1991 | KEEP LAMPS AND REFLECTORS CLEAN | $2,939 | $4,256 | Implemented |
TN0435 # 04 Y:1991 | 04 | 1991 | INSTALL SET-BACK TIMERS | $1,932 | $0 | Implemented |
TN0435 # 05 Y:1991 | 05 | 1991 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $892 | $190 | Implemented |
TN0435 # 06 Y:1991 | 06 | 1991 | COVER OPEN TANKS | $910 | $315 | Implemented |
TN0435 # 07 Y:1991 | 07 | 1991 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $244 | $410 | Implemented |
TN0435 # 08 Y:1991 | 08 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $338 | $322 | Implemented |
TN0435 # 09 Y:1991 | 09 | 1991 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $3,305 | $9,700 | Implemented |
UF0006 # 01 Y:1991 | 01 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,976 | $625 | Not Implemented |
UF0006 # 02 Y:1991 | 02 | 1991 | INSTALL SET-BACK TIMERS | $5,368 | $0 | Not Implemented |
UF0006 # 03 Y:1991 | 03 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $728 | $2,250 | Not Implemented |
UF0006 # 04 Y:1991 | 04 | 1991 | INSTALL SPECTRAL REFLECTORS / DELAMP | $12,654 | $12,570 | Not Implemented |
UF0006 # 05 Y:1991 | 05 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $131 | $245 | Not Implemented |
UF0006 # 06 Y:1991 | 06 | 1991 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $90 | $88 | Not Implemented |
UF0006 # 07 Y:1991 | 07 | 1991 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,148 | $0 | Not Implemented |
MA0213 # 01 Y:1991 | 01 | 1991 | AIR CONDITION ONLY SPACE NECESSARY | $2,708 | $7,000 | Not Implemented |
MA0213 # 02 Y:1991 | 02 | 1991 | REPAIR OR REPLACE STEAM TRAPS | $2,582 | $0 | Not Implemented |
MA0213 # 03 Y:1991 | 03 | 1991 | INSTALL TIMERS AND/OR THERMOSTATS | $246 | $212 | Not Implemented |
MA0213 # 04 Y:1991 | 04 | 1991 | RECOVER WASTE HEAT FROM EQUIPMENT | $911 | $485 | Not Implemented |
MA0213 # 05 Y:1991 | 05 | 1991 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $11,500 | $0 | Not Implemented |