Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
33
matching recommendationsSIC | 3496 | Misc. Fabricated Wire Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0183 # 08 Y:1997 | 08 | 1997 | IMPROVE HANDLING PRACTICES | $12,852 | $6,000 | Not Implemented |
UF0183 # 02 Y:1997 | 02 | 1997 | USE PHOTOCELL CONTROLS | $1,078 | $1,100 | Not Implemented |
UF0183 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,839 | $1,956 | Implemented |
UF0183 # 03 Y:1997 | 03 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,073 | $1,913 | Implemented |
UF0183 # 07 Y:1997 | 07 | 1997 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $58,776 | $0 | Not Implemented |
UF0183 # 04 Y:1997 | 04 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,556 | $1,850 | Implemented |
UF0183 # 05 Y:1997 | 05 | 1997 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,573 | $0 | Not Implemented |
UF0183 # 06 Y:1997 | 06 | 1997 | OPTIMIZE PLANT POWER FACTOR | $9,095 | $36,500 | Not Implemented |
UF0183 # 09 Y:1997 | 09 | 1997 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $18,562 | $8,530 | Not Implemented |
UF0120 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,595 | $54,918 | Implemented |
UF0120 # 07 Y:1995 | 07 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,241 | $5,000 | Not Implemented |
UF0120 # 06 Y:1995 | 06 | 1995 | INSTALL COMMON HEADER ON COMPRESSORS | $3,282 | $2,500 | Not Implemented |
UF0120 # 05 Y:1995 | 05 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,217 | $850 | Implemented |
UF0120 # 04 Y:1995 | 04 | 1995 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $1,769 | $520 | Not Implemented |
UF0120 # 03 Y:1995 | 03 | 1995 | REPLACE ELECTRIC REHEAT WITH HEAT PIPES | $2,103 | $3,500 | Not Implemented |
UF0120 # 02 Y:1995 | 02 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $730 | $4,270 | Implemented |
UF0013 # 10 Y:1991 | 10 | 1991 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,713 | $20,700 | Implemented |
UF0013 # 02 Y:1991 | 02 | 1991 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $18,637 | $34,000 | Implemented |
UF0013 # 09 Y:1991 | 09 | 1991 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $756 | $880 | Implemented |
UF0013 # 08 Y:1991 | 08 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,841 | $3,067 | Implemented |
UF0013 # 07 Y:1991 | 07 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,089 | $1,892 | Implemented |
UF0013 # 06 Y:1991 | 06 | 1991 | KEEP LAMPS AND REFLECTORS CLEAN | $6,364 | $0 | Implemented |
UF0013 # 05 Y:1991 | 05 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,775 | $21,477 | Implemented |
UF0013 # 04 Y:1991 | 04 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,964 | $0 | Implemented |
UF0013 # 01 Y:1991 | 01 | 1991 | OPTIMIZE PLANT POWER FACTOR | $27,648 | $34,850 | Implemented |