Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
45
matching recommendationsSIC | 3496 | Misc. Fabricated Wire Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0586 # 01 Y:1999 | 01 | 1999 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,100 | $7,000 | Not Implemented |
OK0586 # 02 Y:1999 | 02 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,117 | $6,500 | Implemented |
OK0586 # 03 Y:1999 | 03 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,681 | $1,000 | Implemented |
OK0586 # 04 Y:1999 | 04 | 1999 | USE PRECIPITATING AGENTS IN WASTE WATER TREATMENT THAT PRODUCE THE LEAST QUANTITY OF WASTE | $14,440 | $30,000 | Implemented |
OK0586 # 05 Y:1999 | 05 | 1999 | MOVE PRODUCT USING MECHANICAL MEANS | $81,900 | $50,000 | Not Implemented |
OK0586 # 06 Y:1999 | 06 | 1999 | IMPROVE SPACE COMFORT CONDITIONING | $22,750 | $50,000 | Implemented |
BD0146 # 05 Y:1999 | 05 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $858 | $600 | Implemented |
BD0146 # 08 Y:1999 | 08 | 1999 | PAY BILLS ON TIME TO AVOID LATE FEES | $331 | $0 | Not Implemented |
BD0146 # 07 Y:1999 | 07 | 1999 | INSTALL AUTOMATIC PACKING EQUIPMENT | $10,639 | $7,000 | Not Implemented |
BD0146 # 06 Y:1999 | 06 | 1999 | TREAT AND REUSE EQUIPMENT CLEANING SOLUTIONS | $4,333 | $6,500 | Not Implemented |
BD0146 # 04 Y:1999 | 04 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,884 | $2,040 | Not Implemented |
BD0146 # 03 Y:1999 | 03 | 1999 | INSTALL OCCUPANCY SENSORS | $2,118 | $1,200 | Implemented |
BD0146 # 02 Y:1999 | 02 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,176 | $5,900 | Not Implemented |
BD0146 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,411 | $23,585 | Not Implemented |
KU0529 # 01 Y:1999 | 01 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $660 | $190 | Not Implemented |
KU0529 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $600 | $930 | Implemented |
KU0529 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $360 | $700 | Implemented |
KU0529 # 04 Y:1999 | 04 | 1999 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $4,840 | $840 | Implemented |
UD0580 # 09 Y:1999 | 09 | 1999 | SWITCH TO A SOLVENT THAT CAN BE CLEANED AND RE-USED | $1,418 | $0 | Not Implemented |
UD0580 # 01 Y:1999 | 01 | 1999 | USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT | $862,392 | $1,300,000 | Not Implemented |
UD0580 # 02 Y:1999 | 02 | 1999 | ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS | $134,400 | $400,000 | Not Implemented |
UD0580 # 03 Y:1999 | 03 | 1999 | RECOVER AND REUSE COOLING WATER | $52,000 | $140,000 | Not Implemented |
UD0580 # 04 Y:1999 | 04 | 1999 | MOVE PRODUCT USING MECHANICAL MEANS | $39,393 | $10,000 | Not Implemented |
UD0580 # 05 Y:1999 | 05 | 1999 | USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER | $27,840 | $3,500 | Implemented |
UD0580 # 06 Y:1999 | 06 | 1999 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $27,804 | $11,744 | Implemented |