Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
31
matching recommendationsSIC | 3498 | Fabricated Pipe And Fittings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0469 # 07 Y:2013 | 07 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,550 | $4,036 | Implemented |
WV0469 # 11 Y:2013 | 11 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $314 | $56 | Implemented |
WV0469 # 09 Y:2013 | 09 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,378 | $70 | Implemented |
WV0469 # 06 Y:2013 | 06 | 2013 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $5,514 | $1,000 | Implemented |
WV0469 # 12 Y:2013 | 12 | 2013 | DEVELOP A REPAIR/REPLACE POLICY | $77 | $281 | Not Implemented |
WV0469 # 08 Y:2013 | 08 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,484 | $2,292 | Not Implemented |
WV0469 # 05 Y:2013 | 05 | 2013 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $6,853 | $5,700 | Not Implemented |
WV0469 # 04 Y:2013 | 04 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,996 | $0 | Implemented |
WV0469 # 03 Y:2013 | 03 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,896 | $10,694 | Not Implemented |
WV0469 # 02 Y:2013 | 02 | 2013 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $11,090 | $1,989 | Implemented |
WV0469 # 01 Y:2013 | 01 | 2013 | OPTIMIZE PLANT POWER FACTOR | $21,317 | $6,300 | Not Implemented |
WV0469 # 10 Y:2013 | 10 | 2013 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $706 | $460 | Not Implemented |
WV0286 # 07 Y:2004 | 07 | 2004 | DEVELOP A REPAIR/REPLACE POLICY | $1,083 | $375 | Not Implemented |
WV0286 # 12 Y:2004 | 12 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $318 | $250 | Implemented |
WV0286 # 11 Y:2004 | 11 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $743 | $1,100 | Implemented |
WV0286 # 10 Y:2004 | 10 | 2004 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $828 | $283 | Implemented |
WV0286 # 09 Y:2004 | 09 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $830 | $0 | Implemented |
WV0286 # 08 Y:2004 | 08 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $993 | $1,000 | Not Implemented |
WV0286 # 06 Y:2004 | 06 | 2004 | INSULATE BARE EQUIPMENT | $1,353 | $251 | Implemented |
WV0286 # 05 Y:2004 | 05 | 2004 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,455 | $1,770 | Implemented |
WV0286 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,971 | $250 | Implemented |
WV0286 # 03 Y:2004 | 03 | 2004 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,072 | $360 | Implemented |
WV0286 # 02 Y:2004 | 02 | 2004 | OPTIMIZE PLANT POWER FACTOR | $4,469 | $3,580 | Implemented |
WV0286 # 01 Y:2004 | 01 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,216 | $7,012 | Not Implemented |
UD0289 # 05 Y:1989 | 05 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $356 | $75 | Implemented |