IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

527

matching recommendations
Reset
SIC 3498 Fabricated Pipe And Fittings
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0289 # 03 Y:1989 03 1989 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,150 $4,000 Not Implemented
UD0289 # 04 Y:1989 04 1989 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $791 $1,000 Not Implemented
UD0289 # 05 Y:1989 05 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $356 $75 Implemented
UD0289 # 06 Y:1989 06 1989 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $9,331 $25,000 Not Implemented
UD0289 # 07 Y:1989 07 1989 RECOVER AND REUSE COOLING WATER $5,791 $20,000 Not Implemented
OK0265 # 01 Y:1988 01 1988 INSTALL TIMERS AND/OR THERMOSTATS $204 $450 Implemented
OK0265 # 02 Y:1988 02 1988 IMPROVE LUBRICATION PRACTICES $2,711 $0 Implemented
OK0265 # 03 Y:1988 03 1988 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,364 $901 Implemented
OK0265 # 04 Y:1988 04 1988 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,423 $15 Implemented
OK0265 # 05 Y:1988 05 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,790 $4,590 Not Implemented
OK0265 # 06 Y:1988 06 1988 USE RADIANT HEATER FOR SPOT HEATING $1,900 $4,720 Not Implemented
OK0265 # 07 Y:1988 07 1988 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $53,297 $0 Implemented
OK0249 # 01 Y:1988 01 1988 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $956 $0 Not Implemented
OK0249 # 02 Y:1988 02 1988 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,980 $0 Implemented
OK0249 # 03 Y:1988 03 1988 INSTALL TIMERS AND/OR THERMOSTATS $1,682 $1,800 Implemented
OK0249 # 04 Y:1988 04 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $209 $490 Implemented
OK0249 # 05 Y:1988 05 1988 INSTALL SET-BACK TIMERS $104 $0 Not Implemented
AT0058 # 01 Y:1986 01 1986 COVER OPEN TANKS $1,676 $200 Implemented
AT0058 # 02 Y:1986 02 1986 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,183 $0 Not Implemented
AT0058 # 03 Y:1986 03 1986 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $2,928 $1,200 Implemented
AT0058 # 04 Y:1986 04 1986 RECOVER WASTE HEAT FROM EQUIPMENT $520 $300 Not Implemented
AT0058 # 05 Y:1986 05 1986 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $159 $280 Implemented
LT0069 # 01 Y:1986 01 1986 INSTALL TIMERS AND/OR THERMOSTATS $1,700 $1,350 Implemented
LT0069 # 02 Y:1986 02 1986 AIR CONDITION ONLY SPACE NECESSARY $590 $0 Implemented
LT0069 # 03 Y:1986 03 1986 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,540 $3,300 Implemented