Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
547
matching recommendationsSIC | 3498 | Fabricated Pipe And Fittings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0469 # 10 Y:2013 | 10 | 2013 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $706 | $460 | Not Implemented |
WV0469 # 11 Y:2013 | 11 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $314 | $56 | Implemented |
WV0469 # 12 Y:2013 | 12 | 2013 | DEVELOP A REPAIR/REPLACE POLICY | $77 | $281 | Not Implemented |
OK0851 # 01 Y:2013 | 01 | 2013 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $3,442 | $0 | Not Implemented |
OK0851 # 02 Y:2013 | 02 | 2013 | OPTIMIZE PLANT POWER FACTOR | $6,232 | $14,940 | Not Implemented |
OK0851 # 03 Y:2013 | 03 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,912 | $6,000 | Not Implemented |
OK0851 # 04 Y:2013 | 04 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $647 | $1,132 | Not Implemented |
OK0851 # 05 Y:2013 | 05 | 2013 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $7,400 | $44,200 | Implemented |
OK0851 # 06 Y:2013 | 06 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,400 | $1,900 | Implemented |
OK0844 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,922 | $21,000 | Implemented |
OK0844 # 02 Y:2013 | 02 | 2013 | OPTIMIZE PLANT POWER FACTOR | $6,000 | $32,130 | Not Implemented |
OK0844 # 03 Y:2013 | 03 | 2013 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $11,299 | $76,750 | Implemented |
OK0844 # 04 Y:2013 | 04 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,154 | $4,200 | Implemented |
OK0844 # 05 Y:2013 | 05 | 2013 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $6,800 | $18,500 | Not Implemented |
TT0069 # 01 Y:2011 | 01 | 2011 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,768 | $0 | Not Implemented |
TT0069 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,271 | $3,600 | Not Implemented |
TT0069 # 03 Y:2011 | 03 | 2011 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $549 | $600 | Not Implemented |
TT0069 # 04 Y:2011 | 04 | 2011 | OPTIMIZE PLANT POWER FACTOR | $985 | $1,980 | Not Implemented |
TT0069 # 05 Y:2011 | 05 | 2011 | IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS | $2,083 | $4,900 | Not Implemented |
LL0340 # 10 Y:2010 | 10 | 2010 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $225 | $312 | Not Implemented |
LL0340 # 09 Y:2010 | 09 | 2010 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $356 | $425 | Implemented |
LL0340 # 01 Y:2010 | 01 | 2010 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $13,551 | $1,457 | Implemented |
LL0340 # 02 Y:2010 | 02 | 2010 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $13,537 | $450 | Not Implemented |
LL0340 # 03 Y:2010 | 03 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,760 | $1,600 | Implemented |
LL0340 # 04 Y:2010 | 04 | 2010 | USE PHOTOCELL CONTROLS | $4,851 | $210 | Implemented |