Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,117
matching recommendationsSIC | 3499 | Fabricated Metal Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0038 # 03 Y:2014 | 03 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,678 | $1,768 | Implemented |
WM0038 # 04 Y:2014 | 04 | 2014 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $622 | $500 | Implemented |
WM0038 # 05 Y:2014 | 05 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $637 | $1,519 | Implemented |
WM0038 # 06 Y:2014 | 06 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $965 | $880 | Not Implemented |
WM0038 # 07 Y:2014 | 07 | 2014 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $151 | $105 | Not Implemented |
WM0038 # 08 Y:2014 | 08 | 2014 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,319 | $0 | Not Implemented |
WM0038 # 09 Y:2014 | 09 | 2014 | TURN OFF EQUIPMENT WHEN NOT IN USE | $149 | $460 | Implemented |
OK0867 # 01 Y:2013 | 01 | 2013 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $8,579 | $6,400 | Not Implemented |
OK0867 # 02 Y:2013 | 02 | 2013 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $1,208 | $3,900 | Implemented |
OK0867 # 03 Y:2013 | 03 | 2013 | INSTALL SET-BACK TIMERS | $3,386 | $894 | Not Implemented |
OK0867 # 04 Y:2013 | 04 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,837 | $21,300 | Implemented |
OK0867 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,294 | $2,444 | Not Implemented |
OK0867 # 06 Y:2013 | 06 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,712 | $500 | Implemented |
OK0867 # 07 Y:2013 | 07 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $747 | $1,909 | Not Implemented |
OK0867 # 08 Y:2013 | 08 | 2013 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $346 | $701 | Implemented |
OK0867 # 09 Y:2013 | 09 | 2013 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,228 | $4,333 | Not Implemented |
OK0867 # 10 Y:2013 | 10 | 2013 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $74 | $0 | Not Implemented |
OK0867 # 11 Y:2013 | 11 | 2013 | INSULATE BARE EQUIPMENT | $15 | $44 | Implemented |
NC0491 # 01 Y:2013 | 01 | 2013 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $13,288 | $25,000 | Not Implemented |
NC0491 # 02 Y:2013 | 02 | 2013 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $5,220 | $31,024 | Not Implemented |
NC0491 # 03 Y:2013 | 03 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,560 | $4,950 | Not Implemented |
NC0491 # 04 Y:2013 | 04 | 2013 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $2,591 | $10,980 | Not Implemented |
NC0491 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,248 | $11,314 | Implemented |
NC0491 # 06 Y:2013 | 06 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $576 | $100 | Implemented |
UM0425 # 01 Y:2013 | 01 | 2013 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $9,900 | $13,000 | Not Implemented |