Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,117

matching recommendations
Reset
SIC 3499 Fabricated Metal Products, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TT0079 # 07 Y:2011 07 2011 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $5,691 $0 Not Implemented
TT0079 # 08 Y:2011 08 2011 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $4,584 $0 Not Implemented
UD0841 # 01 Y:2011 01 2011 OPTIMIZE PLANT POWER FACTOR $8,191 $20,000 Not Implemented
UD0841 # 02 Y:2011 02 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $88,915 $80,000 Implemented
UD0841 # 03 Y:2011 03 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $50,283 $40,000 Implemented
UD0841 # 04 Y:2011 04 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,101 $30,000 Implemented
UD0841 # 05 Y:2011 05 2011 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $43,664 $0 Implemented
UD0841 # 06 Y:2011 06 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $29,362 $500 Implemented
UD0841 # 07 Y:2011 07 2011 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $22,760 $500 Not Implemented
UD0841 # 08 Y:2011 08 2011 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $12,228 $18,342 Not Implemented
UD0841 # 09 Y:2011 09 2011 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT $1,228 $750 Not Implemented
UD0841 # 10 Y:2011 10 2011 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $42,803 $110,624 Implemented
UD0841 # 11 Y:2011 11 2011 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $65,429 $1,000 Not Implemented
UD0841 # 12 Y:2011 12 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $11,884 $56,000 Not Implemented
UD0841 # 13 Y:2011 13 2011 INSTALL / REPAIR INSULATION ON STEAM LINES $417 $1,012 Implemented
UD0841 # 14 Y:2011 14 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $64,796 $20,000 Implemented
UD0841 # 15 Y:2011 15 2011 ISOLATE HOT OR COLD EQUIPMENT $33,356 $2,000 Implemented
UD0841 # 16 Y:2011 16 2011 INSTALL AUTOMATIC STACK DAMPER $20,178 $500 Not Implemented
UD0841 # 17 Y:2011 17 2011 INSTALL AUTOMATIC STACK DAMPER $20,941 $600 Implemented
UD0841 # 18 Y:2011 18 2011 INSTALL / REPAIR INSULATION ON STEAM LINES $2,133 $2,098 Implemented
UD0841 # 19 Y:2011 19 2011 REDUCE VENTILATION AIR $174,913 $242,291 Not Implemented
UD0841 # 20 Y:2011 20 2011 USE RADIANT HEATER FOR SPOT HEATING $4,098 $17,940 Not Implemented
UD0841 # 21 Y:2011 21 2011 USE RADIANT HEATER FOR SPOT HEATING $2,147 $4,000 Not Implemented
NC0426 # 01 Y:2011 01 2011 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,495 $2,825 Not Implemented
NC0426 # 02 Y:2011 02 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $815 $1,530 Implemented