Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,093
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0207 # 04 Y:1986 | 04 | 1986 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $2,124 | $8,200 | Implemented |
OK0207 # 05 Y:1986 | 05 | 1986 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $2,466 | $1,200 | Implemented |
LT0061 # 01 Y:1986 | 01 | 1986 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,073 | $1,100 | Implemented |
LT0061 # 02 Y:1986 | 02 | 1986 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $406 | $27 | Implemented |
LT0061 # 03 Y:1986 | 03 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,701 | $491 | Implemented |
KU0200 # 01 Y:1986 | 01 | 1986 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,229 | $14,500 | Implemented |
KU0200 # 02 Y:1986 | 02 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,130 | $1,000 | Implemented |
KU0200 # 03 Y:1986 | 03 | 1986 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,694 | $0 | Implemented |
KU0200 # 04 Y:1986 | 04 | 1986 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $473 | $0 | Implemented |
KU0200 # 05 Y:1986 | 05 | 1986 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $198 | $0 | Implemented |
KU0200 # 07 Y:1986 | 07 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $116 | $150 | Implemented |
OK0195 # 01 Y:1986 | 01 | 1986 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,989 | $500 | Implemented |
OK0195 # 03 Y:1986 | 03 | 1986 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $2,520 | $3,000 | Implemented |
OK0195 # 04 Y:1986 | 04 | 1986 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $12,902 | $0 | Implemented |
OK0195 # 05 Y:1986 | 05 | 1986 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $1,289 | $1,200 | Implemented |
OK0195 # 06 Y:1986 | 06 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $582 | $0 | Implemented |
OK0195 # 07 Y:1986 | 07 | 1986 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $2,030 | $1,200 | Implemented |
OK0193 # 02 Y:1986 | 02 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $315 | $126 | Implemented |
OK0193 # 03 Y:1986 | 03 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $270 | $568 | Implemented |
OK0193 # 04 Y:1986 | 04 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $310 | $100 | Implemented |
OK0193 # 06 Y:1986 | 06 | 1986 | INSTALL TIMERS AND/OR THERMOSTATS | $539 | $1,650 | Implemented |
OK0193 # 07 Y:1986 | 07 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $594 | $513 | Implemented |
UD0196 # 02 Y:1986 | 02 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,528 | $2,300 | Implemented |
UD0198 # 01 Y:1986 | 01 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,294 | $3,569 | Implemented |
UD0198 # 02 Y:1986 | 02 | 1986 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $630 | $2,000 | Implemented |