Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
445
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0183 # 03 Y:2000 | 03 | 2000 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $3,631 | $7,500 | Not Implemented |
NC0183 # 04 Y:2000 | 04 | 2000 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $5,091 | $3,300 | Implemented |
NC0183 # 05 Y:2000 | 05 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $884 | $600 | Implemented |
NC0183 # 06 Y:2000 | 06 | 2000 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,983 | $10,750 | Not Implemented |
NC0183 # 07 Y:2000 | 07 | 2000 | USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS | $13,598 | $12,000 | Not Implemented |
NC0183 # 08 Y:2000 | 08 | 2000 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $6,838 | $3,700 | Implemented |
NC0183 # 09 Y:2000 | 09 | 2000 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $500 | $500 | Not Implemented |
NC0183 # 10 Y:2000 | 10 | 2000 | SCHEDULE DELIVERIES ACCORDING TO DEMAND | $20,448 | $5,000 | Implemented |
NC0170 # 01 Y:1999 | 01 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,515 | $0 | Implemented |
NC0170 # 02 Y:1999 | 02 | 1999 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,345 | $500 | Not Implemented |
NC0170 # 03 Y:1999 | 03 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,462 | $2,000 | Implemented |
NC0170 # 04 Y:1999 | 04 | 1999 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $2,763 | $200 | Not Implemented |
NC0170 # 05 Y:1999 | 05 | 1999 | USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS | $29,116 | $20,000 | Not Implemented |
NC0170 # 06 Y:1999 | 06 | 1999 | MINIMIZE WATER USAGE | $3,900 | $50 | Not Implemented |
NC0163 # 01 Y:1999 | 01 | 1999 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $11,222 | $17,000 | Implemented |
NC0163 # 02 Y:1999 | 02 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,614 | $1,600 | Implemented |
NC0163 # 03 Y:1999 | 03 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,866 | $25 | Implemented |
NC0163 # 04 Y:1999 | 04 | 1999 | COVER OPEN TANKS | $24,515 | $21,000 | Not Implemented |
NC0163 # 05 Y:1999 | 05 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $19,985 | $35,000 | Not Implemented |
NC0163 # 06 Y:1999 | 06 | 1999 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $4,068 | $1,000 | Implemented |
NC0163 # 07 Y:1999 | 07 | 1999 | TREAT AND REUSE RINSE WATERS | $7,389 | $4,500 | Implemented |
NC0163 # 08 Y:1999 | 08 | 1999 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $55,000 | $14,000 | Implemented |
TN0646 # 01 Y:1998 | 01 | 1998 | REPROCESS SPENT OILS ON SITE FOR RE-USE | $603,410 | $51,350 | Implemented |
TN0646 # 02 Y:1998 | 02 | 1998 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $28,800 | $21,900 | Implemented |
TN0646 # 03 Y:1998 | 03 | 1998 | ADD AREA LIGHTING SWITCHES | $8,900 | $13,600 | Implemented |