Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
356
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UL0188 # 04 Y:1997 | 04 | 1997 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $2,408 | $17,500 | Not Implemented |
UL0188 # 03 Y:1997 | 03 | 1997 | USE ABSORPTION, EXTRACTION TO REMOVE CONTAMINANTS | $2,103 | $36 | Not Implemented |
UL0188 # 02 Y:1997 | 02 | 1997 | WASH AND REUSE RAGS ON-SITE | $1,313 | $1,640 | Not Implemented |
UL0188 # 01 Y:1997 | 01 | 1997 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $566 | $1,100 | Implemented |
ND0282 # 01 Y:1997 | 01 | 1997 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $8,615 | $500 | Not Implemented |
ND0282 # 02 Y:1997 | 02 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,081 | $1,292 | Implemented |
ND0282 # 03 Y:1997 | 03 | 1997 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $3,450 | $1,000 | Not Implemented |
ND0282 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,130 | $1,005 | Not Implemented |
ND0282 # 05 Y:1997 | 05 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,055 | $500 | Not Implemented |
ND0282 # 06 Y:1997 | 06 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $866 | $460 | Implemented |
ND0282 # 07 Y:1997 | 07 | 1997 | INSTALL OCCUPANCY SENSORS | $724 | $1,000 | Not Implemented |
ND0282 # 08 Y:1997 | 08 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $571 | $108 | Not Implemented |
ND0282 # 09 Y:1997 | 09 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $482 | $910 | Not Implemented |
ND0282 # 10 Y:1997 | 10 | 1997 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $360 | $0 | Not Implemented |
ND0282 # 11 Y:1997 | 11 | 1997 | DISCONNECT BALLASTS | $92 | $150 | Implemented |
ND0282 # 12 Y:1997 | 12 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $72 | $50 | Implemented |
ND0267 # 01 Y:1997 | 01 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,292 | $3,164 | n/a |
ND0267 # 02 Y:1997 | 02 | 1997 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,150 | $290 | n/a |
ND0267 # 03 Y:1997 | 03 | 1997 | OPTIMIZE PLANT POWER FACTOR | $1,062 | $1,418 | n/a |
ND0267 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $661 | $340 | n/a |
ND0267 # 05 Y:1997 | 05 | 1997 | INSTALL OCCUPANCY SENSORS | $546 | $400 | n/a |
ND0267 # 06 Y:1997 | 06 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $70 | $320 | n/a |
ND0267 # 07 Y:1997 | 07 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $381 | $83 | n/a |
ND0267 # 08 Y:1997 | 08 | 1997 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,869 | $260 | n/a |
ND0267 # 09 Y:1997 | 09 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $830 | $280 | n/a |