Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,195
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0411 # 03 Y:2010 | 03 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,958 | $3,705 | Implemented |
WV0411 # 04 Y:2010 | 04 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $2,081 | $3,392 | Not Implemented |
WV0390 # 01 Y:2009 | 01 | 2009 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $138,137 | $122,000 | Not Implemented |
WV0390 # 02 Y:2009 | 02 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $29,790 | $72,987 | Implemented |
WV0390 # 03 Y:2009 | 03 | 2009 | OPTIMIZE PLANT POWER FACTOR | $20,264 | $4,490 | Implemented |
WV0390 # 04 Y:2009 | 04 | 2009 | USE RADIANT HEATER FOR SPOT HEATING | $20,144 | $22,048 | Not Implemented |
WV0390 # 05 Y:2009 | 05 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $16,484 | $11,250 | Not Implemented |
WV0390 # 06 Y:2009 | 06 | 2009 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $15,354 | $2,490 | Implemented |
WV0390 # 07 Y:2009 | 07 | 2009 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $15,020 | $2,500 | Implemented |
WV0390 # 08 Y:2009 | 08 | 2009 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $10,650 | $0 | Implemented |
WV0390 # 09 Y:2009 | 09 | 2009 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,395 | $0 | Implemented |
WV0390 # 10 Y:2009 | 10 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,698 | $3,136 | Not Implemented |
WV0390 # 11 Y:2009 | 11 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,238 | $4,744 | Implemented |
WV0390 # 12 Y:2009 | 12 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,219 | $582 | Not Implemented |
WV0390 # 13 Y:2009 | 13 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $246 | $326 | Implemented |
UD0794 # 01 Y:2009 | 01 | 2009 | REDESIGN PROCESS | $60,982 | $300,000 | Not Implemented |
UD0794 # 02 Y:2009 | 02 | 2009 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $46,758 | $0 | Not Implemented |
UD0794 # 03 Y:2009 | 03 | 2009 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $20,779 | $50,000 | Not Implemented |
UD0794 # 04 Y:2009 | 04 | 2009 | UPGRADE CONTROLS ON COMPRESSORS | $9,841 | $10,000 | Not Implemented |
UD0794 # 05 Y:2009 | 05 | 2009 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $7,981 | $19,425 | Not Implemented |
UD0794 # 06 Y:2009 | 06 | 2009 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $6,273 | $1,000 | Not Implemented |
UD0794 # 07 Y:2009 | 07 | 2009 | UPGRADE CONTROLS ON COMPRESSORS | $3,255 | $0 | Implemented |
UD0794 # 08 Y:2009 | 08 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,202 | $0 | Implemented |
UD0794 # 09 Y:2009 | 09 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,223 | $1,000 | Implemented |
UD0793 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,450 | $25,000 | Implemented |