Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

603

matching recommendations
Reset
SIC 35 Industrial Machinery And Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LM0001 # 06 Y:2001 06 2001 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $18,500 $600 Implemented
LM0001 # 07 Y:2001 07 2001 OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES $12,500 $0 Implemented
SF0212 # 01 Y:2001 01 2001 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $847 $1,513 Implemented
SF0212 # 02 Y:2001 02 2001 INSTALL OCCUPANCY SENSORS $261 $600 Implemented
SF0212 # 03 Y:2001 03 2001 INSULATE BARE EQUIPMENT $422 $1,536 Not Implemented
SF0212 # 04 Y:2001 04 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $953 $4,666 Implemented
SF0212 # 05 Y:2001 05 2001 INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION $18,923 $15,000 Not Implemented
SD0266 # 01 Y:2001 01 2001 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,560 $5,000 Not Implemented
SD0266 # 02 Y:2001 02 2001 INSTALL SKYLIGHTS $8,646 $16,500 Not Implemented
SD0266 # 03 Y:2001 03 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,892 $210 Not Implemented
SD0266 # 04 Y:2001 04 2001 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,776 $1,500 Not Implemented
SD0266 # 05 Y:2001 05 2001 TURN OFF EQUIPMENT WHEN NOT IN USE $517 $100 Not Implemented
SD0266 # 06 Y:2001 06 2001 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS $158,100 $114,362 Not Implemented
SD0266 # 07 Y:2001 07 2001 INSTALL EQUIPMENT TO MOVE PRODUCT $52,020 $10,000 Not Implemented
SD0266 # 08 Y:2001 08 2001 INSTALL AUTOMATIC PACKING EQUIPMENT $6,772 $3,400 Implemented
NV0170 # 01 Y:2000 01 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $10,657 $360 Implemented
NV0170 # 02 Y:2000 02 2000 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $1,709 $95 Not Implemented
NV0170 # 03 Y:2000 03 2000 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $985 $100 Implemented
NV0170 # 04 Y:2000 04 2000 RECOVER AND REUSE WASTE MATERIAL $8,109 $14,542 Implemented
NV0157 # 01 Y:2000 01 2000 BURN A LESS EXPENSIVE GRADE OF FUEL $33,074 $25 Not Implemented
NV0157 # 02 Y:2000 02 2000 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $2,588 $700 Not Implemented
NV0157 # 03 Y:2000 03 2000 REUSE / RECYCLE/ SELL PAPER PRODUCTS $96 $0 Not Implemented
NV0157 # 04 Y:2000 04 2000 REUSE / RECYCLE/ SELL PAPER PRODUCTS $84 $0 Not Implemented
NV0157 # 05 Y:2000 05 2000 INSTALL EQUIPMENT TO MOVE PRODUCT $191,450 $250,000 Not Implemented
NV0157 # 06 Y:2000 06 2000 ELIMINATE SHIFT $41,600 $7,395 Not Implemented