Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
547
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0342 # 04 Y:1991 | 04 | 1991 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,753 | $500 | Not Implemented |
KU0342 # 05 Y:1991 | 05 | 1991 | DE-ENERGIZE EXCESS TRANSFORMER CAPACITY | $4,942 | $100,000 | Not Implemented |
KU0342 # 06 Y:1991 | 06 | 1991 | INSTALL SET-BACK TIMERS | $2,678 | $550 | Not Implemented |
KU0342 # 07 Y:1991 | 07 | 1991 | REDUCE VENTILATION AIR | $1,195 | $200 | Not Implemented |
KU0342 # 08 Y:1991 | 08 | 1991 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $325 | $0 | Not Implemented |
KU0339 # 01 Y:1991 | 01 | 1991 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $4,004 | $700 | Implemented |
KU0339 # 02 Y:1991 | 02 | 1991 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,315 | $1,860 | Implemented |
KU0339 # 03 Y:1991 | 03 | 1991 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $1,071 | $0 | Implemented |
KU0339 # 04 Y:1991 | 04 | 1991 | USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER | $1,066 | $525 | Implemented |
KU0339 # 05 Y:1991 | 05 | 1991 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $577 | $350 | Implemented |
KU0339 # 06 Y:1991 | 06 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $83 | $119 | Implemented |
KU0339 # 07 Y:1991 | 07 | 1991 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $415 | $0 | Implemented |
KU0339 # 08 Y:1991 | 08 | 1991 | TURN OFF EQUIPMENT WHEN NOT IN USE | $144 | $0 | Implemented |
OK0311 # 01 Y:1990 | 01 | 1990 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,239 | $2,150 | Implemented |
OK0311 # 02 Y:1990 | 02 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $2,549 | $750 | Implemented |
OK0311 # 03 Y:1990 | 03 | 1990 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,942 | $1,641 | Not Implemented |
OK0311 # 04 Y:1990 | 04 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $578 | $190 | Implemented |
OK0311 # 05 Y:1990 | 05 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,396 | $0 | Implemented |
OK0311 # 06 Y:1990 | 06 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,283 | $632 | Not Implemented |
OK0311 # 07 Y:1990 | 07 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,494 | $975 | Implemented |
KU0254 # 01 Y:1988 | 01 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,185 | $2,000 | Implemented |
KU0254 # 02 Y:1988 | 02 | 1988 | INSTALL TIMERS AND/OR THERMOSTATS | $191 | $0 | Not Implemented |
KU0254 # 03 Y:1988 | 03 | 1988 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $1,539 | $0 | Implemented |
KU0254 # 04 Y:1988 | 04 | 1988 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $1,773 | $1,800 | Not Implemented |
KU0254 # 05 Y:1988 | 05 | 1988 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $347 | $0 | Implemented |