Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
15,265
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0358 # 07 Y:2011 | 07 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $729 | $919 | Not Implemented |
LL0358 # 08 Y:2011 | 08 | 2011 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $333 | $160 | Not Implemented |
LL0358 # 09 Y:2011 | 09 | 2011 | INSTALL OCCUPANCY SENSORS | $304 | $700 | Not Implemented |
OK0817 # 01 Y:2011 | 01 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,438 | $510 | Implemented |
OK0817 # 02 Y:2011 | 02 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,812 | $1,220 | Not Implemented |
OK0817 # 03 Y:2011 | 03 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,613 | $2,745 | Not Implemented |
OK0817 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $728 | $2,751 | Not Implemented |
OK0817 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $29,469 | $55,540 | Not Implemented |
OK0817 # 06 Y:2011 | 06 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,965 | $47,375 | Not Implemented |
OK0817 # 07 Y:2011 | 07 | 2011 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $5,011 | $23,400 | Implemented |
OK0817 # 08 Y:2011 | 08 | 2011 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $2,546 | $12,837 | Not Implemented |
OK0817 # 09 Y:2011 | 09 | 2011 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,450 | $4,260 | Not Implemented |
OK0817 # 10 Y:2011 | 10 | 2011 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,371 | $0 | Implemented |
IA0473 # 01 Y:2011 | 01 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $695 | $1,100 | Not Implemented |
IA0473 # 02 Y:2011 | 02 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,500 | $105 | Implemented |
IA0473 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,238 | $4,669 | Implemented |
IA0473 # 04 Y:2011 | 04 | 2011 | INSTALL OCCUPANCY SENSORS | $1,472 | $426 | Not Implemented |
IA0473 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $615 | $1,273 | Implemented |
IA0473 # 06 Y:2011 | 06 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $468 | $954 | Not Implemented |
MI0213 # 01 Y:2011 | 01 | 2011 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $5,935 | $14,200 | Not Implemented |
MI0213 # 02 Y:2011 | 02 | 2011 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $4,640 | $1,300 | Implemented |
MI0213 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,899 | $4,000 | Not Implemented |
MI0213 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,184 | $1,320 | Not Implemented |
MI0213 # 05 Y:2011 | 05 | 2011 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $1,255 | $350 | Not Implemented |
MI0213 # 06 Y:2011 | 06 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,430 | $1,860 | Implemented |