Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
299
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0897 # 01 Y:2014 | 01 | 2014 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $5,056 | $0 | Implemented |
OK0897 # 03 Y:2014 | 03 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,796 | $2,066 | Implemented |
OK0897 # 05 Y:2014 | 05 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,000 | $10,067 | Implemented |
OK0893 # 05 Y:2014 | 05 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $480 | $250 | Implemented |
OK0893 # 03 Y:2014 | 03 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $428 | $1,867 | Not Implemented |
OK0893 # 02 Y:2014 | 02 | 2014 | INSTALL OCCUPANCY SENSORS | $1,270 | $1,850 | Not Implemented |
OK0893 # 01 Y:2014 | 01 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,552 | $16,400 | Implemented |
OK0893 # 04 Y:2014 | 04 | 2014 | INSTALL COMMON HEADER ON COMPRESSORS | $1,497 | $700 | Implemented |
OK0862 # 02 Y:2013 | 02 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,745 | $52,650 | Not Implemented |
OK0862 # 05 Y:2013 | 05 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,426 | $53,400 | Not Implemented |
OK0862 # 04 Y:2013 | 04 | 2013 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $600 | $0 | Not Implemented |
OK0862 # 07 Y:2013 | 07 | 2013 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $7,599 | $12,000 | Not Implemented |
OK0862 # 03 Y:2013 | 03 | 2013 | INSTALL OCCUPANCY SENSORS | $3,000 | $2,520 | Implemented |
OK0862 # 01 Y:2013 | 01 | 2013 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $2,733 | $0 | Implemented |
OK0862 # 06 Y:2013 | 06 | 2013 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $2,177 | $8,000 | Not Implemented |
OK0854 # 05 Y:2013 | 05 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $830 | $0 | Implemented |
OK0854 # 04 Y:2013 | 04 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,783 | $1,188 | Implemented |
OK0854 # 03 Y:2013 | 03 | 2013 | INSTALL OCCUPANCY SENSORS | $1,391 | $2,535 | Implemented |
OK0854 # 02 Y:2013 | 02 | 2013 | OPTIMIZE PLANT POWER FACTOR | $3,180 | $6,300 | Not Implemented |
OK0854 # 01 Y:2013 | 01 | 2013 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $3,342 | $0 | Implemented |
OK0854 # 06 Y:2013 | 06 | 2013 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $19,559 | $94,000 | Not Implemented |
OK0820 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $35,642 | $42,504 | Not Implemented |
OK0820 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,502 | $19,152 | Not Implemented |
OK0820 # 01 Y:2012 | 01 | 2012 | USE RADIANT HEATER FOR SPOT HEATING | $16,400 | $24,800 | Not Implemented |
OK0820 # 05 Y:2012 | 05 | 2012 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $9,300 | $10,250 | Not Implemented |