Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
15,137
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0444 # 05 Y:1999 | 05 | 1999 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $230 | $0 | Implemented |
OK0581 # 01 Y:1999 | 01 | 1999 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $11,374 | $1,400 | n/a |
OK0581 # 02 Y:1999 | 02 | 1999 | BURN A LESS EXPENSIVE GRADE OF FUEL | $-2,220 | $2,395 | n/a |
OK0581 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,695 | $340 | n/a |
OK0581 # 04 Y:1999 | 04 | 1999 | INSTALL OCCUPANCY SENSORS | $568 | $1,098 | n/a |
OK0581 # 05 Y:1999 | 05 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $218 | $224 | n/a |
OK0581 # 06 Y:1999 | 06 | 1999 | $24,960 | $31,000 | n/a | |
OK0581 # 07 Y:1999 | 07 | 1999 | RECOVER AND REUSE WASTE MATERIAL | $2,370 | $2,000 | n/a |
MS0140 # 01 Y:1999 | 01 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,728 | $790 | Implemented |
MS0140 # 02 Y:1999 | 02 | 1999 | OPTIMIZE PLANT POWER FACTOR | $7,639 | $7,425 | Not Implemented |
MS0140 # 03 Y:1999 | 03 | 1999 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $4,814 | $1,440 | Not Implemented |
MS0140 # 04 Y:1999 | 04 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,213 | $2,922 | Implemented |
MS0140 # 05 Y:1999 | 05 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $666 | $389 | Implemented |
MS0140 # 06 Y:1999 | 06 | 1999 | INSTALL TIMERS AND/OR THERMOSTATS | $11,408 | $1,299 | Implemented |
MS0140 # 07 Y:1999 | 07 | 1999 | BURN WASTE OIL FOR HEAT | $5,179 | $4,416 | Not Implemented |
MS0140 # 08 Y:1999 | 08 | 1999 | $45,000 | $19,688 | Implemented | |
UM0145 # 01 Y:1999 | 01 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,720 | $300 | Implemented |
UM0145 # 02 Y:1999 | 02 | 1999 | USE RADIANT HEATER FOR SPOT HEATING | $2,157 | $4,500 | Not Implemented |
UM0145 # 03 Y:1999 | 03 | 1999 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $14,970 | $40,000 | Not Implemented |
UM0145 # 04 Y:1999 | 04 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $8,978 | $11,600 | Not Implemented |
UM0145 # 05 Y:1999 | 05 | 1999 | USE REVERSE OSMOSIS TO CONCENTRATE MATERIAL | $50,143 | $85,000 | Not Implemented |
UM0145 # 06 Y:1999 | 06 | 1999 | USE ABSORPTION, EXTRACTION TO REMOVE CONTAMINANTS | $24,222 | $60,000 | Implemented |
UM0145 # 07 Y:1999 | 07 | 1999 | $16,869 | $14,495 | Implemented | |
UM0145 # 08 Y:1999 | 08 | 1999 | $32,500 | $2,000 | Not Implemented | |
CO0443 # 01 Y:1999 | 01 | 1999 | TURN OFF EQUIPMENT WHEN NOT IN USE | $16,960 | $0 | Implemented |