IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

147

matching recommendations
Reset
SIC 35 Industrial Machinery And Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0065 # 06 Y:1989 06 1989 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $640 $2,750 Not Implemented
MA0151 # 01 Y:1989 01 1989 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $5,228 $426 Not Implemented
MA0151 # 02 Y:1989 02 1989 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN $1,218 $305 Not Implemented
MA0151 # 03 Y:1989 03 1989 RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS $4,308 $243 Not Implemented
MA0151 # 04 Y:1989 04 1989 BURN A LESS EXPENSIVE GRADE OF FUEL $12,509 $15,150 Implemented
MA0151 # 05 Y:1989 05 1989 DIRECT WARMEST AIR TO COMBUSTION INTAKE $1,022 $593 Implemented
MA0151 # 06 Y:1989 06 1989 USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC $1,093 $592 Not Implemented
MA0151 # 07 Y:1989 07 1989 RECOVER WASTE HEAT FROM EQUIPMENT $2,050 $3,150 Not Implemented
UD0291 # 01 Y:1989 01 1989 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,548 $6,000 Not Implemented
UD0291 # 02 Y:1989 02 1989 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,832 $15,000 Implemented
UD0291 # 03 Y:1989 03 1989 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $851 $500 Implemented
UD0291 # 04 Y:1989 04 1989 USE DIRECT AIR SUPPLY TO EXHAUST HOODS $2,237 $4,000 Not Implemented
UD0291 # 05 Y:1989 05 1989 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,866 $2,000 Implemented
WI0056 # 01 Y:1989 01 1989 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $35,807 $0 Implemented
WI0056 # 02 Y:1989 02 1989 INSTALL TIMERS AND/OR THERMOSTATS $34,447 $11,000 Implemented
WI0056 # 03 Y:1989 03 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,617 $12,685 Implemented
WI0056 # 04 Y:1989 04 1989 USE DEMAND CONTROLLER OR LOAD SHEDDER $5,544 $5,000 Implemented
WI0056 # 05 Y:1989 05 1989 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $2,914 $0 Not Implemented
WI0056 # 06 Y:1989 06 1989 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $1,809 $2,000 Not Implemented
WI0056 # 07 Y:1989 07 1989 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $1,681 $5,000 Implemented
WI0056 # 08 Y:1989 08 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,664 $500 Implemented
WI0056 # 09 Y:1989 09 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,120 $0 Not Implemented
AM0062 # 01 Y:1989 01 1989 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $2,350 $3,160 Not Implemented
AM0062 # 02 Y:1989 02 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,090 $7,752 Not Implemented
AM0062 # 03 Y:1989 03 1989 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $1,440 $2,000 Not Implemented