Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
15,265
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0013 # 06 Y:1994 | 06 | 1994 | USE RADIANT HEATER FOR SPOT HEATING | $2,649 | $6,400 | Not Implemented |
SF0039 # 01 Y:1994 | 01 | 1994 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $2,078 | $4,752 | Not Implemented |
SF0039 # 02 Y:1994 | 02 | 1994 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $10,590 | $2,750 | Implemented |
SF0039 # 03 Y:1994 | 03 | 1994 | INSULATE BARE EQUIPMENT | $2,733 | $3,713 | Implemented |
SF0039 # 04 Y:1994 | 04 | 1994 | INSTALL OCCUPANCY SENSORS | $2,811 | $2,400 | Implemented |
SF0039 # 05 Y:1994 | 05 | 1994 | ADD AREA LIGHTING SWITCHES | $1,444 | $130 | Implemented |
SF0039 # 06 Y:1994 | 06 | 1994 | OPTIMIZE PLANT POWER FACTOR | $2,458 | $4,153 | Not Implemented |
SF0039 # 07 Y:1994 | 07 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,811 | $2,759 | Implemented |
OR0217 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,943 | $5,465 | Implemented |
OR0217 # 02 Y:1994 | 02 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,072 | $15,891 | Implemented |
OR0217 # 03 Y:1994 | 03 | 1994 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $1,880 | $3,200 | Implemented |
OR0217 # 04 Y:1994 | 04 | 1994 | MINIMIZE CONTAMINATION OF WATER BEFORE TREATMENT | $8,519 | $20,000 | Not Implemented |
OR0217 # 05 Y:1994 | 05 | 1994 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $2,470 | $0 | Implemented |
UF0095 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $32,948 | $39,507 | Implemented |
UF0095 # 02 Y:1994 | 02 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,388 | $1,750 | Implemented |
UF0095 # 03 Y:1994 | 03 | 1994 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $16,867 | $24,660 | Implemented |
UF0095 # 04 Y:1994 | 04 | 1994 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $6,763 | $22,550 | Not Implemented |
UF0095 # 05 Y:1994 | 05 | 1994 | REPLACE ELECTRIC REHEAT WITH HEAT PIPES | $11,259 | $38,450 | Not Implemented |
UF0095 # 06 Y:1994 | 06 | 1994 | MAKE ICE DURING OFF PEAK HOURS FOR COOLING | $49,423 | $76,330 | Not Implemented |
UF0095 # 07 Y:1994 | 07 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $554 | $794 | Implemented |
KU0442 # 01 Y:1994 | 01 | 1994 | INSTALL SKYLIGHTS | $7,072 | $35,400 | Not Implemented |
KU0442 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,001 | $8,058 | Not Implemented |
KU0442 # 03 Y:1994 | 03 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,523 | $4,449 | Implemented |
KU0442 # 04 Y:1994 | 04 | 1994 | INSTALL OCCUPANCY SENSORS | $390 | $900 | Not Implemented |
KU0442 # 05 Y:1994 | 05 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $381 | $360 | Implemented |