Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

547

matching recommendations
Reset
SIC 35 Industrial Machinery And Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0965 # 09 Y:2017 09 2017 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $159 $0 Not Implemented
OK0965 # 10 Y:2017 10 2017 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $3,351 $0 Implemented
OK0842 # 01 Y:2013 01 2013 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $21,170 $53,000 Not Implemented
OK0842 # 02 Y:2013 02 2013 USE RADIANT HEATER FOR SPOT HEATING $52,275 $107,250 Not Implemented
OK0842 # 03 Y:2013 03 2013 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $52,815 $21,105 Implemented
OK0842 # 04 Y:2013 04 2013 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $7,057 $128,411 Implemented
OK0842 # 05 Y:2013 05 2013 UTILIZE A LESS EXPENSIVE COOLING METHOD $242,685 $1,298,400 Not Implemented
OK0842 # 06 Y:2013 06 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $664 $5,625 Not Implemented
OK0842 # 07 Y:2013 07 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,837 $5,254 Not Implemented
OK0842 # 08 Y:2013 08 2013 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $8,801 $21,780 Implemented
OK0842 # 09 Y:2013 09 2013 RECOVER WASTE HEAT FROM EQUIPMENT $24,000 $1,708 Not Implemented
OK0842 # 10 Y:2013 10 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $22,770 $5,000 Implemented
OK0842 # 11 Y:2013 11 2013 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $5,138 $7,536 Not Implemented
OK0842 # 12 Y:2013 12 2013 OPTIMIZE PLANT POWER FACTOR $18,213 $10,212 Not Implemented
OK0842 # 13 Y:2013 13 2013 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $32,965 $56,937 Not Implemented
OK0815 # 01 Y:2011 01 2011 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $57,281 $13,000 Not Implemented
OK0815 # 02 Y:2011 02 2011 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $12,351 $0 Implemented
OK0815 # 03 Y:2011 03 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,341 $930 Implemented
OK0815 # 04 Y:2011 04 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $340 $950 Implemented
OK0815 # 05 Y:2011 05 2011 INSTALL OCCUPANCY SENSORS $2,608 $2,198 Not Implemented
OK0815 # 06 Y:2011 06 2011 DISCONNECT BALLASTS $849 $696 Not Implemented
OK0815 # 07 Y:2011 07 2011 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $15,876 $3,096 Not Implemented
OK0815 # 08 Y:2011 08 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $9,335 $20,544 Not Implemented
OK0815 # 09 Y:2011 09 2011 INSULATE BARE EQUIPMENT $3,531 $633 Implemented
OK0799 # 01 Y:2010 01 2010 IMPROVE COMBUSTION CONTROL CAPABILITY $58,238 $1,003 Not Implemented