Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
15,260
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0002 # 05 Y:1991 | 05 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $251 | $2,520 | Implemented |
UF0002 # 06 Y:1991 | 06 | 1991 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $6,167 | $5,300 | Implemented |
UF0002 # 07 Y:1991 | 07 | 1991 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $15,029 | $0 | Implemented |
AM0120 # 01 Y:1991 | 01 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,000 | $0 | Not Implemented |
AM0120 # 02 Y:1991 | 02 | 1991 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,950 | $215 | Not Implemented |
AM0120 # 03 Y:1991 | 03 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,506 | $0 | Not Implemented |
AM0120 # 04 Y:1991 | 04 | 1991 | INSTALL SET-BACK TIMERS | $1,250 | $0 | Not Implemented |
AM0120 # 05 Y:1991 | 05 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,050 | $1,960 | Not Implemented |
AM0120 # 06 Y:1991 | 06 | 1991 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $650 | $680 | Not Implemented |
AM0120 # 07 Y:1991 | 07 | 1991 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $640 | $50 | Not Implemented |
AM0120 # 08 Y:1991 | 08 | 1991 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $290 | $350 | Not Implemented |
KU0336 # 01 Y:1991 | 01 | 1991 | RECOVER WASTE HEAT FROM EQUIPMENT | $21,491 | $19,500 | Implemented |
KU0336 # 02 Y:1991 | 02 | 1991 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $15,055 | $18,000 | Implemented |
KU0336 # 03 Y:1991 | 03 | 1991 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $12,114 | $27,600 | Implemented |
KU0336 # 04 Y:1991 | 04 | 1991 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,818 | $3,800 | Implemented |
KU0336 # 05 Y:1991 | 05 | 1991 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $22,099 | $22,000 | Implemented |
KU0336 # 06 Y:1991 | 06 | 1991 | REDESIGN PROCESS | $10,585 | $25,200 | Implemented |
KU0336 # 07 Y:1991 | 07 | 1991 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $5,650 | $17,100 | Implemented |
KU0336 # 08 Y:1991 | 08 | 1991 | DE-ENERGIZE EXCESS TRANSFORMER CAPACITY | $1,112 | $0 | Implemented |
KU0336 # 09 Y:1991 | 09 | 1991 | INSTALL SET-BACK TIMERS | $899 | $1,000 | Implemented |
KU0336 # 10 Y:1991 | 10 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $366 | $0 | Implemented |
KU0336 # 11 Y:1991 | 11 | 1991 | RECOVER AND REUSE COOLING WATER | $9,720 | $5,340 | Implemented |
MO0022 # 01 Y:1991 | 01 | 1991 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,566 | $2,267 | Implemented |
MO0022 # 02 Y:1991 | 02 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,956 | $6,256 | Implemented |
MO0022 # 03 Y:1991 | 03 | 1991 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,150 | $60 | Implemented |