Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,027
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0696 # 06 Y:2015 | 06 | 2015 | INSTALL EFFICIENT RECTIFIERS | $375 | $2,000 | Not Implemented |
AM0696 # 07 Y:2015 | 07 | 2015 | INSTALL OCCUPANCY SENSORS | $280 | $630 | Implemented |
AM0696 # 08 Y:2015 | 08 | 2015 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $130 | $0 | Implemented |
AM0690 # 01 Y:2015 | 01 | 2015 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $17,950 | $12,830 | Not Implemented |
AM0690 # 02 Y:2015 | 02 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,320 | $2,000 | Not Implemented |
AM0690 # 03 Y:2015 | 03 | 2015 | OPTIMIZE PLANT POWER FACTOR | $14,550 | $31,640 | Not Implemented |
AM0690 # 04 Y:2015 | 04 | 2015 | OPTIMIZE PLANT POWER FACTOR | $11,210 | $21,860 | Not Implemented |
AM0690 # 05 Y:2015 | 05 | 2015 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $8,400 | $9,800 | Not Implemented |
AM0690 # 06 Y:2015 | 06 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $8,190 | $10,960 | Not Implemented |
AM0690 # 07 Y:2015 | 07 | 2015 | OPTIMIZE PLANT POWER FACTOR | $4,570 | $11,330 | Not Implemented |
AM0690 # 08 Y:2015 | 08 | 2015 | INSTALL OCCUPANCY SENSORS | $4,060 | $1,270 | Not Implemented |
AM0690 # 09 Y:2015 | 09 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,330 | $30 | Not Implemented |
AM0686 # 01 Y:2015 | 01 | 2015 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,770 | $0 | Not Implemented |
AM0686 # 02 Y:2015 | 02 | 2015 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,790 | $0 | Not Implemented |
AM0686 # 03 Y:2015 | 03 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $895 | $5 | Not Implemented |
AM0686 # 04 Y:2015 | 04 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,390 | $5,700 | Not Implemented |
AM0686 # 05 Y:2015 | 05 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $455 | $220 | Not Implemented |
AM0686 # 06 Y:2015 | 06 | 2015 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $12,685 | $17,600 | Not Implemented |
AM0686 # 07 Y:2015 | 07 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,490 | $500 | Not Implemented |
AM0686 # 08 Y:2015 | 08 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,915 | $1,810 | Not Implemented |
AM0686 # 09 Y:2015 | 09 | 2015 | PAY UTILITY BILLS ON TIME | $1,789 | $0 | Not Implemented |
AM0677 # 01 Y:2015 | 01 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,570 | $130,700 | Implemented |
AM0677 # 02 Y:2015 | 02 | 2015 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $22,000 | $1,140 | Implemented |
AM0677 # 03 Y:2015 | 03 | 2015 | INSTALL OCCUPANCY SENSORS | $3,460 | $7,200 | Implemented |
AM0677 # 04 Y:2015 | 04 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,805 | $23 | Not Implemented |