IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

295

matching recommendations
Reset
SIC 35 Industrial Machinery And Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LL0161 # 05 Y:2003 05 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $641 $20 Implemented
LL0161 # 06 Y:2003 06 2003 INSTALL OCCUPANCY SENSORS $534 $520 Not Implemented
LL0161 # 07 Y:2003 07 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $402 $210 Not Implemented
LL0152 # 01 Y:2003 01 2003 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $7,992 $825 Implemented
LL0152 # 02 Y:2003 02 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,007 $0 Implemented
LL0152 # 03 Y:2003 03 2003 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,939 $3,429 Implemented
LL0152 # 04 Y:2003 04 2003 INSTALL OCCUPANCY SENSORS $960 $428 Not Implemented
LL0152 # 05 Y:2003 05 2003 CONTRACT A WOOD PALLET RECYCLING COMPANY $6,240 $0 Not Implemented
LL0152 # 06 Y:2003 06 2003 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $8,995 $12,400 Implemented
LL0151 # 01 Y:2003 01 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $15,605 $4,350 Implemented
LL0151 # 02 Y:2003 02 2003 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $15,140 $4,600 Not Implemented
LL0151 # 03 Y:2003 03 2003 USE PHOTOCELL CONTROLS $10,108 $1,092 Not Implemented
LL0151 # 04 Y:2003 04 2003 INSTALL OCCUPANCY SENSORS $5,710 $494 Not Implemented
LL0151 # 05 Y:2003 05 2003 ELIMINATE LEAKS IN COMBUSTIBLE GAS LINES $3,410 $1,240 Implemented
LL0151 # 06 Y:2003 06 2003 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,284 $180 Implemented
LL0151 # 07 Y:2003 07 2003 FILTER AND REUSE HYDRAULIC OIL $40,689 $8,000 Implemented
LL0151 # 08 Y:2003 08 2003 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $9,556 $12,425 Implemented
LL0148 # 01 Y:2002 01 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $23,222 $10,500 Implemented
LL0148 # 02 Y:2002 02 2002 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $17,996 $32,600 Implemented
LL0148 # 03 Y:2002 03 2002 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $6,584 $0 Not Implemented
LL0148 # 04 Y:2002 04 2002 OPTIMIZE PLANT POWER FACTOR $5,475 $10,500 Implemented
LL0148 # 05 Y:2002 05 2002 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,293 $0 Not Implemented
LL0149 # 01 Y:2002 01 2002 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $1,932 $1,499 Implemented
LL0149 # 02 Y:2002 02 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,591 $210 Not Implemented
LL0149 # 03 Y:2002 03 2002 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,237 $0 Not Implemented