Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
335
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0260 # 07 Y:1992 | 07 | 1992 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $84,970 | $120,000 | Implemented |
CO0260 # 05 Y:1992 | 05 | 1992 | COVER OPEN TANKS | $13,870 | $4,000 | Implemented |
CO0260 # 04 Y:1992 | 04 | 1992 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $8,920 | $8,750 | Implemented |
CO0260 # 12 Y:1992 | 12 | 1992 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $14,750 | $20,280 | Implemented |
CO0260 # 11 Y:1992 | 11 | 1992 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $106 | $900 | Implemented |
CO0260 # 10 Y:1992 | 10 | 1992 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $300 | $150 | Implemented |
CO0260 # 06 Y:1992 | 06 | 1992 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $176,510 | $40,000 | Implemented |
CO0260 # 09 Y:1992 | 09 | 1992 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $5,880 | $7,700 | Implemented |
CO0260 # 08 Y:1992 | 08 | 1992 | INSULATE BARE EQUIPMENT | $1,500 | $700 | Implemented |
CO0260 # 03 Y:1992 | 03 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,820 | $310 | Implemented |
CO0260 # 02 Y:1992 | 02 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,880 | $500 | Implemented |
CO0260 # 14 Y:1992 | 14 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $820 | $2,610 | Implemented |
CO0260 # 01 Y:1992 | 01 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,200 | $1,000 | Implemented |
CO0260 # 13 Y:1992 | 13 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,130 | $2,870 | Implemented |
MA0259 # 05 Y:1992 | 05 | 1992 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $686 | $2,108 | Not Implemented |
MA0259 # 02 Y:1992 | 02 | 1992 | BURN A LESS EXPENSIVE GRADE OF FUEL | $3,084 | $0 | Not Implemented |
MA0259 # 06 Y:1992 | 06 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $584 | $0 | Not Implemented |
MA0259 # 08 Y:1992 | 08 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $292 | $180 | Not Implemented |
MA0259 # 03 Y:1992 | 03 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $487 | $0 | Not Implemented |
MA0259 # 07 Y:1992 | 07 | 1992 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $396 | $168 | Not Implemented |
MA0259 # 01 Y:1992 | 01 | 1992 | REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY | $8,134 | $0 | Not Implemented |
MA0259 # 04 Y:1992 | 04 | 1992 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $562 | $509 | Not Implemented |
ND0046 # 02 Y:1992 | 02 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $582 | $4,765 | Implemented |
ND0046 # 03 Y:1992 | 03 | 1992 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $1,535 | $1,200 | Not Implemented |
ND0046 # 04 Y:1992 | 04 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $582 | $300 | Implemented |