Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

437

matching recommendations
Reset
SIC 35 Industrial Machinery And Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UU0037 # 04 Y:2002 04 2002 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,174 $20 Not Implemented
UU0037 # 05 Y:2002 05 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,586 $230 Not Implemented
UU0037 # 01 Y:2002 01 2002 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $1,120 $0 Not Implemented
UU0037 # 03 Y:2002 03 2002 OPTIMIZE PLANT POWER FACTOR $1,896 $2,861 Not Implemented
UU0037 # 02 Y:2002 02 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $675 $420 Not Implemented
LE0150 # 01 Y:2002 01 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $642 $500 Implemented
LE0150 # 02 Y:2002 02 2002 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $1,303 $2,400 Implemented
LE0150 # 03 Y:2002 03 2002 INSTALL TIMERS AND/OR THERMOSTATS $2,256 $1,050 Implemented
OK0649 # 02 Y:2002 02 2002 INSTALL OCCUPANCY SENSORS $104 $37 Implemented
OK0649 # 05 Y:2002 05 2002 $397,966 $600,000 Not Implemented
OK0649 # 03 Y:2002 03 2002 RECOVER WASTE HEAT FROM EQUIPMENT $16,238 $35,000 Not Implemented
OK0649 # 04 Y:2002 04 2002 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $1,706 $2,520 Not Implemented
OK0649 # 01 Y:2002 01 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,956 $3,504 Implemented
AM0422 # 04 Y:2002 04 2002 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $780 $50 Implemented
AM0422 # 07 Y:2002 07 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $345 $310 Implemented
AM0422 # 06 Y:2002 06 2002 OPTIMIZE PLANT POWER FACTOR $375 $840 Not Implemented
AM0422 # 05 Y:2002 05 2002 PAY UTILITY BILLS ON TIME $645 $0 Implemented
AM0422 # 03 Y:2002 03 2002 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,545 $30 Implemented
AM0422 # 02 Y:2002 02 2002 $13,580 $5,270 Implemented
AM0422 # 08 Y:2002 08 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $140 $50 Implemented
AM0422 # 01 Y:2002 01 2002 $47,350 $110,240 Not Implemented
SU0144 # 08 Y:2002 08 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $255 $75 Implemented
SU0144 # 05 Y:2002 05 2002 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $649 $2,150 Not Implemented
SU0144 # 09 Y:2002 09 2002 $252 $40 Not Implemented
SU0144 # 06 Y:2002 06 2002 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $586 $0 Not Implemented