Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
481
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TA0086 # 03 Y:2004 | 03 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,950 | $5,000 | Not Implemented |
TA0086 # 05 Y:2004 | 05 | 2004 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,605 | $2,000 | Not Implemented |
TA0086 # 02 Y:2004 | 02 | 2004 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,520 | $5,800 | Not Implemented |
TA0086 # 04 Y:2004 | 04 | 2004 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,350 | $0 | Not Implemented |
TA0086 # 01 Y:2004 | 01 | 2004 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,742 | $0 | Not Implemented |
UU0072 # 03 Y:2004 | 03 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $16,150 | $17,500 | Not Implemented |
UU0072 # 05 Y:2004 | 05 | 2004 | INSTALL OCCUPANCY SENSORS | $940 | $600 | Not Implemented |
UU0072 # 02 Y:2004 | 02 | 2004 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $10,670 | $10,000 | Not Implemented |
UU0072 # 06 Y:2004 | 06 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $203,380 | $800,000 | Not Implemented |
UU0072 # 01 Y:2004 | 01 | 2004 | OPTIMIZE PLANT POWER FACTOR | $17,050 | $21,660 | Not Implemented |
UU0072 # 07 Y:2004 | 07 | 2004 | REPROCESS SPENT OILS ON SITE FOR RE-USE | $34,700 | $6,000 | Not Implemented |
UU0072 # 04 Y:2004 | 04 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,450 | $8,500 | Not Implemented |
MI0096 # 03 Y:2004 | 03 | 2004 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $6,619 | $150 | Implemented |
MI0096 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $-147 | $1,015 | Not Implemented |
MI0096 # 01 Y:2004 | 01 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,113 | $800 | Not Implemented |
MI0096 # 07 Y:2004 | 07 | 2004 | COVER OPEN TANKS | $34 | $25 | Implemented |
MI0096 # 06 Y:2004 | 06 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $110 | $56 | Implemented |
MI0096 # 02 Y:2004 | 02 | 2004 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $3,213 | $1,250 | Implemented |
MI0096 # 05 Y:2004 | 05 | 2004 | USE SYNTHETIC LUBRICANT | $696 | $189 | Not Implemented |
IC0088 # 02 Y:2004 | 02 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,571 | $20,087 | Not Implemented |
IC0088 # 06 Y:2004 | 06 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,547 | $400 | Implemented |
IC0088 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,563 | $459 | Implemented |
IC0088 # 04 Y:2004 | 04 | 2004 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $3,021 | $21,693 | Not Implemented |
IC0088 # 01 Y:2004 | 01 | 2004 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,664 | $0 | Implemented |
IC0088 # 05 Y:2004 | 05 | 2004 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $505 | $1,420 | Not Implemented |