Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
255
matching recommendationsSIC | 3519 | Internal Combustion Engines, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0148 # 08 Y:2007 | 08 | 2007 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $452 | $160 | Not Implemented |
IC0109 # 01 Y:2005 | 01 | 2005 | MODIFY WORKLOAD | $25,000 | $0 | Implemented |
IC0109 # 02 Y:2005 | 02 | 2005 | INSTALL WASTE HEAT BOILER TO PRODUCE STEAM | $437,212 | $3,259,200 | Not Implemented |
IC0109 # 03 Y:2005 | 03 | 2005 | REPLACE BOILER | $294,938 | $501,372 | Not Implemented |
IC0109 # 04 Y:2005 | 04 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $17,632 | $22,464 | Not Implemented |
IC0109 # 05 Y:2005 | 05 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $1,239 | $400 | Implemented |
IC0109 # 06 Y:2005 | 06 | 2005 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $37,809 | $131,160 | Not Implemented |
IC0109 # 07 Y:2005 | 07 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $36,496 | $2,100 | Implemented |
LE0190 # 01 Y:2004 | 01 | 2004 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $65,403 | $20,000 | Implemented |
LE0190 # 02 Y:2004 | 02 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $17,844 | $50,000 | Not Implemented |
LE0190 # 03 Y:2004 | 03 | 2004 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,450 | $2,500 | Not Implemented |
LE0190 # 04 Y:2004 | 04 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,412 | $750 | Not Implemented |
LE0190 # 05 Y:2004 | 05 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,074 | $218 | Implemented |
LE0190 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,187 | $33,512 | Implemented |
MS0140 # 01 Y:1999 | 01 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,728 | $790 | Implemented |
MS0140 # 02 Y:1999 | 02 | 1999 | OPTIMIZE PLANT POWER FACTOR | $7,639 | $7,425 | Not Implemented |
MS0140 # 03 Y:1999 | 03 | 1999 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $4,814 | $1,440 | Not Implemented |
MS0140 # 04 Y:1999 | 04 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,213 | $2,922 | Implemented |
MS0140 # 05 Y:1999 | 05 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $666 | $389 | Implemented |
MS0140 # 06 Y:1999 | 06 | 1999 | INSTALL TIMERS AND/OR THERMOSTATS | $11,408 | $1,299 | Implemented |
MS0140 # 07 Y:1999 | 07 | 1999 | BURN WASTE OIL FOR HEAT | $5,179 | $4,416 | Not Implemented |
MS0140 # 08 Y:1999 | 08 | 1999 | IMPROVE SPACE COMFORT CONDITIONING | $45,000 | $19,688 | Implemented |
TP0001 # 01 Y:1999 | 01 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $4,643 | $3,384 | Not Implemented |
TP0001 # 02 Y:1999 | 02 | 1999 | OPTIMIZE PLANT POWER FACTOR | $2,340 | $3,500 | Implemented |
TP0001 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,870 | $7,300 | Not Implemented |