Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
864
matching recommendationsSIC | 352 | Farm And Garden Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0204 # 08 Y:2005 | 08 | 2005 | OPTIMIZE PLANT POWER FACTOR | $3,731 | $11,931 | Not Implemented |
SU0203 # 01 Y:2005 | 01 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,139 | $0 | Not Implemented |
SU0203 # 02 Y:2005 | 02 | 2005 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $9,582 | $0 | Not Implemented |
SU0203 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,367 | $366 | Implemented |
SU0203 # 04 Y:2005 | 04 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,129 | $308 | Implemented |
SU0203 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,105 | $960 | Implemented |
SU0203 # 06 Y:2005 | 06 | 2005 | INSTALL OCCUPANCY SENSORS | $1,344 | $1,090 | Not Implemented |
SU0203 # 07 Y:2005 | 07 | 2005 | INSTALL SOLID WASTE INCINERATOR FOR HEAT | $16,477 | $25,850 | Not Implemented |
AS0384 # 01 Y:2004 | 01 | 2004 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $58,500 | $1,130 | Not Implemented |
AS0384 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $34,877 | $495 | Not Implemented |
AS0384 # 03 Y:2004 | 03 | 2004 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $26,000 | $22,316 | Implemented |
AS0384 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,206 | $88,805 | Not Implemented |
AS0384 # 05 Y:2004 | 05 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,859 | $180 | Implemented |
AS0384 # 06 Y:2004 | 06 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,696 | $3,600 | Not Implemented |
AS0384 # 07 Y:2004 | 07 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,575 | $20 | Implemented |
AS0384 # 08 Y:2004 | 08 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $904 | $961 | Not Implemented |
AS0384 # 09 Y:2004 | 09 | 2004 | INSULATE BARE EQUIPMENT | $902 | $251 | Implemented |
IA0341 # 01 Y:2004 | 01 | 2004 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $7,506 | $1,200 | Not Implemented |
IA0341 # 02 Y:2004 | 02 | 2004 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $2,502 | $700 | Implemented |
IA0341 # 03 Y:2004 | 03 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,519 | $460 | Implemented |
IA0341 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $727 | $105 | Implemented |
IA0341 # 05 Y:2004 | 05 | 2004 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $8,040 | $54,300 | Implemented |
IA0341 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $182 | $194 | Implemented |
IA0341 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $874 | $1,990 | Implemented |
IA0341 # 08 Y:2004 | 08 | 2004 | INSTALL OCCUPANCY SENSORS | $123 | $289 | Implemented |