Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
864
matching recommendationsSIC | 352 | Farm And Garden Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0675 # 11 Y:2003 | 11 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $525 | $1,750 | Not Implemented |
UD0675 # 12 Y:2003 | 12 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $430 | $100 | Implemented |
UD0675 # 13 Y:2003 | 13 | 2003 | TREAT AND REUSE EQUIPMENT CLEANING SOLUTIONS | $250 | $424 | Not Implemented |
UD0675 # 14 Y:2003 | 14 | 2003 | ADD AREA LIGHTING SWITCHES | $240 | $200 | Not Implemented |
UD0675 # 15 Y:2003 | 15 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $205 | $432 | Implemented |
OR0429 # 01 Y:2003 | 01 | 2003 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $13,080 | $43,350 | Not Implemented |
OR0429 # 02 Y:2003 | 02 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,040 | $7,490 | Not Implemented |
OR0429 # 03 Y:2003 | 03 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,380 | $2,400 | Not Implemented |
OR0429 # 04 Y:2003 | 04 | 2003 | INSTALL COMMON HEADER ON COMPRESSORS | $2,230 | $4,750 | Not Implemented |
OR0429 # 05 Y:2003 | 05 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,025 | $150 | Not Implemented |
OR0429 # 06 Y:2003 | 06 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $509 | $1,800 | Not Implemented |
BD0216 # 01 Y:2002 | 01 | 2002 | USE RADIANT HEATER FOR SPOT HEATING | $44,159 | $52,000 | Not Implemented |
BD0216 # 02 Y:2002 | 02 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,756 | $1,500 | Implemented |
BD0216 # 03 Y:2002 | 03 | 2002 | INSTALL OCCUPANCY SENSORS | $1,635 | $6,230 | Not Implemented |
BD0216 # 04 Y:2002 | 04 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,518 | $1,800 | Implemented |
BD0216 # 05 Y:2002 | 05 | 2002 | INSTALL AUTOMATIC STACK DAMPER | $1,359 | $1,500 | Not Implemented |
BD0216 # 06 Y:2002 | 06 | 2002 | INSTALL OCCUPANCY SENSORS | $937 | $975 | Not Implemented |
BD0216 # 07 Y:2002 | 07 | 2002 | INSTALL TURBULATORS | $813 | $1,700 | Implemented |
BD0216 # 08 Y:2002 | 08 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $399 | $328 | Not Implemented |
BD0216 # 09 Y:2002 | 09 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $387 | $0 | Not Implemented |
BD0216 # 10 Y:2002 | 10 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $221 | $800 | Not Implemented |
BD0216 # 11 Y:2002 | 11 | 2002 | REPAIR AND ELIMINATE STEAM LEAKS | $208 | $300 | Implemented |
BD0216 # 12 Y:2002 | 12 | 2002 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $4,719 | $12,000 | Not Implemented |
BD0216 # 13 Y:2002 | 13 | 2002 | INSTALL AUTOMATIC PACKING EQUIPMENT | $25,880 | $25,000 | Not Implemented |
BD0216 # 14 Y:2002 | 14 | 2002 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $8,000 | $1,000 | Not Implemented |