Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
60
matching recommendationsSIC | 352 | Farm And Garden Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0741 # 07 Y:2006 | 07 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,802 | $840 | Implemented |
UD0741 # 06 Y:2006 | 06 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,387 | $3,150 | Not Implemented |
UD0741 # 05 Y:2006 | 05 | 2006 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $9,135 | $2,800 | Implemented |
UD0741 # 04 Y:2006 | 04 | 2006 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $16,240 | $0 | Implemented |
UD0741 # 03 Y:2006 | 03 | 2006 | INSTALL TIMERS AND/OR THERMOSTATS | $18,067 | $110 | Implemented |
UD0741 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $43,883 | $133,640 | Not Implemented |
UD0741 # 01 Y:2006 | 01 | 2006 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $65,250 | $10,000 | Not Implemented |
UD0741 # 09 Y:2006 | 09 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,261 | $0 | Implemented |
UD0675 # 09 Y:2003 | 09 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,480 | $9,600 | Not Implemented |
UD0675 # 12 Y:2003 | 12 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $430 | $100 | Implemented |
UD0675 # 08 Y:2003 | 08 | 2003 | REDUCE FLUID FLOW RATES | $2,011 | $1,200 | Not Implemented |
UD0675 # 07 Y:2003 | 07 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,355 | $280 | Implemented |
UD0675 # 06 Y:2003 | 06 | 2003 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $3,068 | $384 | Implemented |
UD0675 # 05 Y:2003 | 05 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,130 | $0 | Implemented |
UD0675 # 04 Y:2003 | 04 | 2003 | COMBINE UTILITY METERS | $4,000 | $0 | Not Implemented |
UD0675 # 03 Y:2003 | 03 | 2003 | OPTIMIZE PLANT POWER FACTOR | $7,934 | $2,500 | Not Implemented |
UD0675 # 02 Y:2003 | 02 | 2003 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $10,610 | $1,200 | Implemented |
UD0675 # 10 Y:2003 | 10 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $695 | $0 | Implemented |
UD0675 # 11 Y:2003 | 11 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $525 | $1,750 | Not Implemented |
UD0675 # 13 Y:2003 | 13 | 2003 | TREAT AND REUSE EQUIPMENT CLEANING SOLUTIONS | $250 | $424 | Not Implemented |
UD0675 # 14 Y:2003 | 14 | 2003 | ADD AREA LIGHTING SWITCHES | $240 | $200 | Not Implemented |
UD0675 # 15 Y:2003 | 15 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $205 | $432 | Implemented |
UD0675 # 01 Y:2003 | 01 | 2003 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $26,842 | $625 | Implemented |
UM0094 # 06 Y:1997 | 06 | 1997 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $1,600 | $0 | Not Implemented |
UM0094 # 05 Y:1997 | 05 | 1997 | INSULATE BARE EQUIPMENT | $18,874 | $7,590 | Implemented |