Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
21
matching recommendationsSIC | 352 | Farm And Garden Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DS0083 # 06 Y:1997 | 06 | 1997 | INCREASE USE OF AUTOMATION | $16,770 | $30,000 | Implemented |
DS0083 # 05 Y:1997 | 05 | 1997 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $589 | $352 | Implemented |
DS0083 # 04 Y:1997 | 04 | 1997 | RECOVER AND REUSE WASTE MATERIAL | $3,750 | $4,844 | Implemented |
DS0083 # 03 Y:1997 | 03 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,269 | $256 | Implemented |
DS0083 # 02 Y:1997 | 02 | 1997 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,832 | $1,000 | Not Implemented |
DS0083 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,163 | $7,878 | Implemented |
DS0063 # 04 Y:1996 | 04 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,851 | $20,100 | Not Implemented |
DS0063 # 03 Y:1996 | 03 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $1,305 | $4,750 | Not Implemented |
DS0063 # 02 Y:1996 | 02 | 1996 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $4,215 | $600 | Not Implemented |
DS0063 # 01 Y:1996 | 01 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,301 | $400 | Implemented |
DS0059 # 07 Y:1996 | 07 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,765 | $4,750 | Implemented |
DS0059 # 06 Y:1996 | 06 | 1996 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,029 | $2,400 | Implemented |
DS0059 # 05 Y:1996 | 05 | 1996 | CONVERT TO ELECTROSTATIC POWDER COATING | $17,650 | $6,080 | Implemented |
DS0059 # 04 Y:1996 | 04 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,395 | $260 | Implemented |
DS0059 # 03 Y:1996 | 03 | 1996 | OPTIMIZE PLANT POWER FACTOR | $1,316 | $2,150 | Not Implemented |
DS0059 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,518 | $12,579 | Not Implemented |
DS0059 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $868 | $2,959 | Implemented |
DS0037 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,041 | $33,682 | Not Implemented |
DS0037 # 04 Y:1995 | 04 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $280 | $96 | Not Implemented |
DS0037 # 03 Y:1995 | 03 | 1995 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,247 | $4,096 | Not Implemented |
DS0037 # 02 Y:1995 | 02 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,005 | $2,664 | Not Implemented |