Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
42
matching recommendationsSIC | 353 | Construction And Related Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0070 # 07 Y:2011 | 07 | 2011 | OPTIMIZE PLANT POWER FACTOR | $6,582 | $32,600 | Not Implemented |
TT0070 # 02 Y:2011 | 02 | 2011 | INSULATE BARE EQUIPMENT | $7,025 | $2,100 | Not Implemented |
TT0070 # 01 Y:2011 | 01 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,235 | $0 | Not Implemented |
TT0070 # 06 Y:2011 | 06 | 2011 | IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS | $1,730 | $4,900 | Not Implemented |
TT0070 # 08 Y:2011 | 08 | 2011 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $11,486 | $102,000 | Not Implemented |
TT0070 # 03 Y:2011 | 03 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $1,990 | $1,600 | Not Implemented |
TT0070 # 04 Y:2011 | 04 | 2011 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $875 | $1,200 | Not Implemented |
TT0070 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,337 | $21,600 | Not Implemented |
TT0070 # 09 Y:2011 | 09 | 2011 | DEVELOP A REPAIR/REPLACE POLICY | $5,985 | $1,347 | Not Implemented |
AR0140 # 04 Y:1998 | 04 | 1998 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $3,592 | $3,260 | n/a |
AR0140 # 10 Y:1998 | 10 | 1998 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $66,000 | $1,280 | n/a |
AR0140 # 09 Y:1998 | 09 | 1998 | MOVE PRODUCT USING MECHANICAL MEANS | $66,072 | $3,200 | n/a |
AR0140 # 08 Y:1998 | 08 | 1998 | REDUCE SCRAP PRODUCTION | $14,997 | $18,800 | n/a |
AR0140 # 07 Y:1998 | 07 | 1998 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $46,527 | $1,000 | n/a |
AR0140 # 06 Y:1998 | 06 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $13,190 | $8,000 | n/a |
AR0140 # 05 Y:1998 | 05 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $499 | $279 | n/a |
AR0140 # 03 Y:1998 | 03 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,420 | $130 | n/a |
AR0140 # 02 Y:1998 | 02 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,967 | $250 | n/a |
AR0140 # 01 Y:1998 | 01 | 1998 | OPTIMIZE PLANT POWER FACTOR | $33,786 | $22,860 | n/a |
AR0102 # 02 Y:1996 | 02 | 1996 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,248 | $6,802 | Implemented |
AR0102 # 07 Y:1996 | 07 | 1996 | RECYCLE CLEANING SOLVENT AND REUSE | $12,981 | $6,000 | Implemented |
AR0102 # 06 Y:1996 | 06 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $3,760 | $6,000 | Not Implemented |
AR0102 # 05 Y:1996 | 05 | 1996 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $234 | $30 | Implemented |
AR0102 # 04 Y:1996 | 04 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $147 | $60 | Implemented |
AR0102 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,611 | $390 | Not Implemented |