Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
47
matching recommendationsSIC | 353 | Construction And Related Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0724 # 09 Y:2005 | 09 | 2005 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $3,364 | $0 | Implemented |
UL0173 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $40 | $537 | Not Implemented |
UL0173 # 02 Y:1996 | 02 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $1,502 | $500 | Not Implemented |
UL0173 # 03 Y:1996 | 03 | 1996 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $49 | $0 | Implemented |
UL0173 # 04 Y:1996 | 04 | 1996 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $100 | $190 | Not Implemented |
UL0173 # 05 Y:1996 | 05 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $393 | $0 | Not Implemented |
UL0173 # 06 Y:1996 | 06 | 1996 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $15,930 | $7,600 | Implemented |
ND0221 # 07 Y:1995 | 07 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $609 | $500 | Not Implemented |
ND0221 # 10 Y:1995 | 10 | 1995 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $18,486 | $2,200 | Not Implemented |
ND0221 # 09 Y:1995 | 09 | 1995 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $201 | $180 | Not Implemented |
ND0221 # 08 Y:1995 | 08 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $357 | $375 | Not Implemented |
ND0221 # 06 Y:1995 | 06 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $689 | $5,050 | Not Implemented |
ND0221 # 05 Y:1995 | 05 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $771 | $495 | Not Implemented |
ND0221 # 04 Y:1995 | 04 | 1995 | TURN OFF EQUIPMENT WHEN NOT IN USE | $797 | $650 | Not Implemented |
ND0221 # 03 Y:1995 | 03 | 1995 | TURN OFF EQUIPMENT WHEN NOT IN USE | $800 | $2,000 | Not Implemented |
ND0221 # 02 Y:1995 | 02 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $800 | $600 | Implemented |
ND0221 # 01 Y:1995 | 01 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $874 | $850 | Implemented |
ND0018 # 01 Y:1992 | 01 | 1992 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $21,576 | $62,547 | Not Implemented |
ND0018 # 02 Y:1992 | 02 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,520 | $0 | Not Implemented |
ND0018 # 03 Y:1992 | 03 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,149 | $400 | Not Implemented |
ND0018 # 04 Y:1992 | 04 | 1992 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,895 | $0 | Not Implemented |
ND0018 # 05 Y:1992 | 05 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $149 | $200 | Not Implemented |