Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
126
matching recommendationsSIC | 353 | Construction And Related Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0165 # 07 Y:2021 | 07 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,598 | $3,500 | Not Implemented |
WM0165 # 05 Y:2021 | 05 | 2021 | INSTALL OCCUPANCY SENSORS | $2,370 | $1,800 | Not Implemented |
WM0165 # 08 Y:2021 | 08 | 2021 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,497 | $0 | Not Implemented |
WM0165 # 04 Y:2021 | 04 | 2021 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $2,552 | $6,405 | Not Implemented |
WM0155 # 10 Y:2020 | 10 | 2020 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $360 | $0 | Implemented |
WM0155 # 09 Y:2020 | 09 | 2020 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $366 | $1,250 | Implemented |
WM0155 # 08 Y:2020 | 08 | 2020 | INSTALL OCCUPANCY SENSORS | $451 | $750 | Not Implemented |
WM0155 # 07 Y:2020 | 07 | 2020 | USE PHOTOCELL CONTROLS | $541 | $1,075 | Not Implemented |
WM0155 # 01 Y:2020 | 01 | 2020 | USE SOLAR HEAT TO MAKE ELECTRICTY | $26,709 | $110,788 | Not Implemented |
WM0155 # 02 Y:2020 | 02 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,927 | $8,716 | Not Implemented |
WM0155 # 03 Y:2020 | 03 | 2020 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $2,335 | $1,700 | Not Implemented |
WM0155 # 04 Y:2020 | 04 | 2020 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,791 | $15,060 | Not Implemented |
WM0155 # 05 Y:2020 | 05 | 2020 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,761 | $3,855 | Not Implemented |
WM0155 # 06 Y:2020 | 06 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,679 | $1,750 | Not Implemented |
WM0131 # 04 Y:2019 | 04 | 2019 | USE SYNTHETIC LUBRICANT | $14,757 | $10,000 | Implemented |
WM0131 # 01 Y:2019 | 01 | 2019 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $33,801 | $0 | Not Implemented |
WM0131 # 02 Y:2019 | 02 | 2019 | USE SOLAR HEAT TO MAKE ELECTRICTY | $18,168 | $105,757 | Not Implemented |
WM0131 # 09 Y:2019 | 09 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $455 | $600 | Not Implemented |
WM0131 # 08 Y:2019 | 08 | 2019 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,915 | $0 | Implemented |
WM0131 # 07 Y:2019 | 07 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,069 | $1,500 | Implemented |
WM0131 # 06 Y:2019 | 06 | 2019 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,086 | $4,750 | Implemented |
WM0131 # 05 Y:2019 | 05 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,174 | $15,938 | Not Implemented |
WM0131 # 03 Y:2019 | 03 | 2019 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $18,069 | $5,612 | Implemented |
WM0128 # 02 Y:2018 | 02 | 2018 | USE SOLAR HEAT TO MAKE ELECTRICTY | $20,855 | $48,500 | Not Implemented |
WM0128 # 01 Y:2018 | 01 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $26,391 | $22,752 | Implemented |