Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,768

matching recommendations
Reset
SIC 353 Construction And Related Machinery
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UK1402 # 03 Y:2014 03 2014 MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT $2,530 $1,500 Not Implemented
UK1402 # 04 Y:2014 04 2014 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,833 $0 Not Implemented
UK1402 # 05 Y:2014 05 2014 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $34,700 $40,000 Not Implemented
UK1402 # 06 Y:2014 06 2014 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $1,409 $0 Not Implemented
UK1402 # 07 Y:2014 07 2014 USE PHOTOCELL CONTROLS $1,297 $1,125 Not Implemented
UK1402 # 08 Y:2014 08 2014 INSTALL OCCUPANCY SENSORS $11,101 $3,241 Not Implemented
UK1402 # 09 Y:2014 09 2014 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $552 $524 Not Implemented
BS0033 # 01 Y:2014 01 2014 INSTALL STEAM TRAP $123 $217 Not Implemented
BS0033 # 02 Y:2014 02 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,073 $15 Not Implemented
BS0033 # 03 Y:2014 03 2014 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $263 $168 Not Implemented
BS0033 # 04 Y:2014 04 2014 TURN OFF EQUIPMENT WHEN NOT IN USE $464 $10 Not Implemented
BS0033 # 05 Y:2014 05 2014 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $4,302 $17,525 Not Implemented
BS0033 # 06 Y:2014 06 2014 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $2,800 $2,668 Not Implemented
BS0033 # 07 Y:2014 07 2014 INSTALL OCCUPANCY SENSORS $2,179 $360 Not Implemented
BS0033 # 08 Y:2014 08 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,767 $23,688 Not Implemented
BS0033 # 09 Y:2014 09 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $33 $160 Not Implemented
BS0033 # 10 Y:2014 10 2014 INSTALL TIMERS AND/OR THERMOSTATS $21,246 $1,547 Not Implemented
WV0484 # 03 Y:2014 03 2014 UPGRADE CONTROLS ON COMPRESSORS $11,868 $7,750 Implemented
WV0484 # 09 Y:2014 09 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,489 $6,113 Implemented
WV0484 # 08 Y:2014 08 2014 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,298 $0 Implemented
WV0484 # 07 Y:2014 07 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,693 $468 Implemented
WV0484 # 05 Y:2014 05 2014 USE DEMAND CONTROLLER OR LOAD SHEDDER $6,830 $5,600 Not Implemented
WV0484 # 04 Y:2014 04 2014 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $6,987 $3,690 Not Implemented
WV0484 # 06 Y:2014 06 2014 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $4,252 $4,500 Implemented
WV0484 # 02 Y:2014 02 2014 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $24,659 $51,000 Not Implemented