Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,768
matching recommendationsSIC | 353 | Construction And Related Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0576 # 04 Y:2010 | 04 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,540 | $300 | Implemented |
AM0576 # 05 Y:2010 | 05 | 2010 | INSTALL OCCUPANCY SENSORS | $1,263 | $79 | Implemented |
AM0576 # 06 Y:2010 | 06 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,040 | $760 | Implemented |
AM0576 # 07 Y:2010 | 07 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $757 | $16 | Not Implemented |
AM0576 # 08 Y:2010 | 08 | 2010 | INSTALL SKYLIGHTS | $740 | $1,600 | Not Implemented |
AM0576 # 09 Y:2010 | 09 | 2010 | INSTALL SKYLIGHTS | $450 | $970 | Not Implemented |
AM0576 # 10 Y:2010 | 10 | 2010 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $280 | $300 | Not Implemented |
BD0370 # 01 Y:2010 | 01 | 2010 | INSTALL SKYLIGHTS | $9,511 | $30,250 | Not Implemented |
BD0370 # 02 Y:2010 | 02 | 2010 | INSTALL OCCUPANCY SENSORS | $3,119 | $825 | Not Implemented |
BD0370 # 03 Y:2010 | 03 | 2010 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,319 | $170 | Not Implemented |
BD0370 # 04 Y:2010 | 04 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,464 | $1,500 | Not Implemented |
BD0370 # 05 Y:2010 | 05 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,599 | $0 | Not Implemented |
BD0370 # 06 Y:2010 | 06 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,109 | $1,220 | Not Implemented |
BD0370 # 07 Y:2010 | 07 | 2010 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $26,834 | $15,000 | Not Implemented |
BD0370 # 08 Y:2010 | 08 | 2010 | INSTALL SKYLIGHTS | $18,262 | $9,040 | Not Implemented |
BD0370 # 09 Y:2010 | 09 | 2010 | INSTALL OCCUPANCY SENSORS | $6,679 | $3,600 | Not Implemented |
BD0370 # 10 Y:2010 | 10 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $2,240 | $3,180 | Not Implemented |
NC0396 # 01 Y:2009 | 01 | 2009 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $76,612 | $275,318 | Not Implemented |
NC0396 # 02 Y:2009 | 02 | 2009 | CONDENSE OPERATION INTO ONE BUILDING | $31,185 | $13,100 | Not Implemented |
NC0396 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $37,090 | $83,137 | Not Implemented |
NC0396 # 04 Y:2009 | 04 | 2009 | INSTALL OCCUPANCY SENSORS | $600 | $558 | Not Implemented |
NC0396 # 05 Y:2009 | 05 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $313 | $132 | Not Implemented |
NC0396 # 06 Y:2009 | 06 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,507 | $0 | Not Implemented |
NC0396 # 07 Y:2009 | 07 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,690 | $5,306 | Not Implemented |
AM0554 # 01 Y:2008 | 01 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $213,800 | $45,770 | Implemented |