Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,768
matching recommendationsSIC | 353 | Construction And Related Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0554 # 02 Y:2008 | 02 | 2008 | TURN OFF EQUIPMENT WHEN NOT IN USE | $133,000 | $1,000 | Implemented |
AM0554 # 03 Y:2008 | 03 | 2008 | TURN OFF EQUIPMENT WHEN NOT IN USE | $77,830 | $0 | Not Implemented |
AM0554 # 04 Y:2008 | 04 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $51,670 | $2,000 | Implemented |
AM0554 # 05 Y:2008 | 05 | 2008 | PAY UTILITY BILLS ON TIME | $9,462 | $0 | Implemented |
AM0554 # 06 Y:2008 | 06 | 2008 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,900 | $5,400 | Implemented |
AM0554 # 07 Y:2008 | 07 | 2008 | USE SYNTHETIC LUBRICANT | $3,150 | $0 | Not Implemented |
AM0554 # 08 Y:2008 | 08 | 2008 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,185 | $500 | Implemented |
AM0554 # 09 Y:2008 | 09 | 2008 | SELL OIL TO RECYCLER | $1,240 | $0 | Implemented |
LL0305 # 01 Y:2008 | 01 | 2008 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $15,764 | $1,710 | Not Implemented |
LL0305 # 02 Y:2008 | 02 | 2008 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $8,261 | $1,320 | Implemented |
LL0305 # 03 Y:2008 | 03 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,846 | $3,025 | Implemented |
LL0305 # 04 Y:2008 | 04 | 2008 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $5,230 | $1,470 | Not Implemented |
LL0305 # 05 Y:2008 | 05 | 2008 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,925 | $348 | Implemented |
LL0305 # 06 Y:2008 | 06 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $853 | $490 | Implemented |
LL0305 # 07 Y:2008 | 07 | 2008 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $168 | $160 | Not Implemented |
LE0278 # 01 Y:2008 | 01 | 2008 | UPGRADE OBSOLETE EQUIPMENT | $94,158 | $132,748 | Not Implemented |
LE0278 # 02 Y:2008 | 02 | 2008 | TURN OFF EQUIPMENT WHEN NOT IN USE | $36,970 | $760 | Implemented |
LE0278 # 03 Y:2008 | 03 | 2008 | USE RADIANT HEATER FOR SPOT HEATING | $17,728 | $16,000 | Not Implemented |
LE0278 # 04 Y:2008 | 04 | 2008 | INSTALL TIMERS AND/OR THERMOSTATS | $12,408 | $9,600 | Not Implemented |
LE0278 # 05 Y:2008 | 05 | 2008 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $10,716 | $1,200 | Not Implemented |
LE0278 # 06 Y:2008 | 06 | 2008 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $8,828 | $7,000 | Implemented |
LE0278 # 07 Y:2008 | 07 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,783 | $7,000 | Not Implemented |
LE0278 # 08 Y:2008 | 08 | 2008 | USE OPTIMUM TEMPERATURE | $7,669 | $500 | Not Implemented |
LE0278 # 09 Y:2008 | 09 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,894 | $304 | Not Implemented |
LE0278 # 10 Y:2008 | 10 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,764 | $800 | Not Implemented |