IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,768

matching recommendations
Reset
SIC 353 Construction And Related Machinery
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0388 # 06 Y:2006 06 2006 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,922 $52 Implemented
IA0388 # 07 Y:2006 07 2006 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,279 $1,972 Not Implemented
IA0388 # 08 Y:2006 08 2006 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $47,693 $45,600 Implemented
BD0301 # 01 Y:2006 01 2006 USE RADIANT HEATER FOR SPOT HEATING $94,570 $91,000 Implemented
BD0301 # 02 Y:2006 02 2006 RECOVER WASTE HEAT FROM EQUIPMENT $43,599 $22,780 Implemented
BD0301 # 03 Y:2006 03 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,786 $1,800 Implemented
BD0301 # 04 Y:2006 04 2006 USE PHOTOCELL CONTROLS $1,759 $1,750 Implemented
BD0301 # 05 Y:2006 05 2006 RECOVER WASTE HEAT FROM EQUIPMENT $1,640 $500 Implemented
BD0301 # 06 Y:2006 06 2006 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $911 $1,960 Not Implemented
BD0301 # 07 Y:2006 07 2006 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $763 $500 Implemented
BD0301 # 08 Y:2006 08 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $342 $350 Implemented
BD0301 # 09 Y:2006 09 2006 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $40,050 $22,800 Not Implemented
BD0301 # 10 Y:2006 10 2006 AUTOMATE FINISHING PROCESS $1,669,200 $285,000 Implemented
BD0301 # 11 Y:2006 11 2006 PAY BILLS ON TIME TO AVOID LATE FEES $995 $0 Implemented
LL0240 # 01 Y:2006 01 2006 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $40,093 $2,862 Implemented
LL0240 # 02 Y:2006 02 2006 USE PHOTOCELL CONTROLS $28,394 $1,110 Implemented
LL0240 # 03 Y:2006 03 2006 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $24,138 $143,240 Implemented
LL0240 # 04 Y:2006 04 2006 INSTALL TIMERS AND/OR THERMOSTATS $15,054 $726 Implemented
LL0240 # 05 Y:2006 05 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $11,827 $12,200 Implemented
LL0240 # 06 Y:2006 06 2006 INSTALL OCCUPANCY SENSORS $2,004 $990 Implemented
LL0240 # 07 Y:2006 07 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,657 $1,050 Implemented
LL0240 # 08 Y:2006 08 2006 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $421 $770 Not Implemented
LL0240 # 09 Y:2006 09 2006 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $21,764 $230 Implemented
TA0111 # 01 Y:2005 01 2005 CLEAR AND RENT EXISTING SPACE $225,000 $2,250 Not Implemented
TA0111 # 02 Y:2005 02 2005 AIR CONDITION ONLY SPACE NECESSARY $51,150 $0 Not Implemented