Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,768
matching recommendationsSIC | 353 | Construction And Related Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ME0242 # 07 Y:1998 | 07 | 1998 | USE OPTIMUM THICKNESS INSULATION | $392 | $90 | Not Implemented |
ME0242 # 08 Y:1998 | 08 | 1998 | USE OPTIMUM THICKNESS INSULATION | $90 | $160 | Implemented |
ME0242 # 09 Y:1998 | 09 | 1998 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $4,922 | $3,036 | Implemented |
UM0110 # 01 Y:1998 | 01 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $929 | $100 | Implemented |
UM0110 # 02 Y:1998 | 02 | 1998 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,055 | $11,155 | Not Implemented |
UM0110 # 03 Y:1998 | 03 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $900 | $50 | n/a |
UM0110 # 04 Y:1998 | 04 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $301 | $800 | Not Implemented |
UM0110 # 05 Y:1998 | 05 | 1998 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $3,480 | $1,000 | Implemented |
UM0110 # 06 Y:1998 | 06 | 1998 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $1,394 | $624 | Implemented |
IA0187 # 01 Y:1997 | 01 | 1997 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,822 | $1,825 | Implemented |
IA0187 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,370 | $3,595 | Not Implemented |
IA0187 # 03 Y:1997 | 03 | 1997 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,349 | $3,850 | Not Implemented |
IA0187 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $396 | $922 | Implemented |
IA0187 # 05 Y:1997 | 05 | 1997 | INSTALL OCCUPANCY SENSORS | $448 | $266 | Not Implemented |
IA0187 # 06 Y:1997 | 06 | 1997 | INSTALL TIMERS AND/OR THERMOSTATS | $361 | $384 | Implemented |
IA0187 # 07 Y:1997 | 07 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $140 | $170 | Implemented |
IA0187 # 08 Y:1997 | 08 | 1997 | CONVERT TO ELECTROSTATIC POWDER COATING | $12,006 | $7,800 | Implemented |
IA0187 # 09 Y:1997 | 09 | 1997 | REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT | $3,368 | $1,054 | Implemented |
OK0534 # 01 Y:1997 | 01 | 1997 | USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS | $285,720 | $575,000 | Implemented |
OK0534 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $128,530 | $202,500 | Implemented |
OK0534 # 03 Y:1997 | 03 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,249 | $124,654 | Implemented |
OK0534 # 04 Y:1997 | 04 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $9,484 | $18,600 | Implemented |
OK0534 # 05 Y:1997 | 05 | 1997 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $6,240 | $268,000 | Not Implemented |
OK0534 # 06 Y:1997 | 06 | 1997 | USE COUNTER-CURRENT RINSING TO REDUCE RINSE WATER VOLUME (GRAVURE) | $5,542 | $27,375 | Implemented |
OK0534 # 07 Y:1997 | 07 | 1997 | USE COUNTER-CURRENT RINSING TO REDUCE RINSE WATER VOLUME (GRAVURE) | $5,196 | $1,000 | Implemented |