IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

105

matching recommendations
Reset
SIC 353 Construction And Related Machinery
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LL0124 # 05 Y:2001 05 2001 USE POWER DURING OFF-PEAK PERIODS $45,864 $112,325 Implemented
LL0124 # 06 Y:2001 06 2001 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $83,474 $92,279 Implemented
LL0124 # 04 Y:2001 04 2001 USE PHOTOCELL CONTROLS $2,399 $203 Implemented
LL0124 # 03 Y:2001 03 2001 USE PHOTOCELL CONTROLS $4,948 $406 Implemented
LL0124 # 02 Y:2001 02 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $126,949 $31,740 Implemented
LL0124 # 01 Y:2001 01 2001 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $537,467 $121,200 Implemented
TA0017 # 05 Y:2001 05 2001 USE SYNTHETIC LUBRICANT $130 $0 Not Implemented
TA0017 # 04 Y:2001 04 2001 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $295 $6 Implemented
TA0017 # 03 Y:2001 03 2001 PAY BILLS ON TIME TO AVOID LATE FEES $269 $0 Implemented
TA0017 # 02 Y:2001 02 2001 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $4,400 $0 Implemented
TA0017 # 01 Y:2001 01 2001 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $6,600 $192 Implemented
BD0193 # 02 Y:2001 02 2001 RECOVER WASTE HEAT FROM EQUIPMENT $44,275 $22,875 Implemented
BD0193 # 13 Y:2001 13 2001 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $62,772 $5,000 Implemented
BD0193 # 12 Y:2001 12 2001 REUSE / RECYCLE/ SELL PAPER PRODUCTS $663 $500 Not Implemented
BD0193 # 11 Y:2001 11 2001 CONTRACT A WOOD PALLET RECYCLING COMPANY $700 $180 Not Implemented
BD0193 # 10 Y:2001 10 2001 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $2,710 $7,000 Not Implemented
BD0193 # 09 Y:2001 09 2001 CONVERT TO ELECTROSTATIC POWDER COATING $42,843 $150,000 n/a
BD0193 # 08 Y:2001 08 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $324 $350 Implemented
BD0193 # 07 Y:2001 07 2001 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,352 $1,000 Implemented
BD0193 # 06 Y:2001 06 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,368 $2,660 Implemented
BD0193 # 05 Y:2001 05 2001 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,570 $2,970 Not Implemented
BD0193 # 04 Y:2001 04 2001 INSTALL OCCUPANCY SENSORS $2,922 $1,875 Not Implemented
BD0193 # 03 Y:2001 03 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,104 $2,900 Implemented
BD0193 # 01 Y:2001 01 2001 USE RADIANT HEATER FOR SPOT HEATING $68,706 $29,000 Implemented
LE0118 # 01 Y:2001 01 2001 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,581 $2,500 Not Implemented