Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
52
matching recommendationsSIC | 353 | Construction And Related Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0799 # 12 Y:2010 | 12 | 2010 | INSULATE BARE EQUIPMENT | $623 | $1,230 | Not Implemented |
OK0799 # 01 Y:2010 | 01 | 2010 | IMPROVE COMBUSTION CONTROL CAPABILITY | $58,238 | $1,003 | Not Implemented |
OK0799 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,065 | $9,879 | Not Implemented |
OK0799 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,109 | $19,184 | Not Implemented |
OK0799 # 02 Y:2010 | 02 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,629 | $21,300 | Not Implemented |
OK0799 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,663 | $226,451 | Not Implemented |
OK0799 # 09 Y:2010 | 09 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,489 | $24,789 | Not Implemented |
OK0799 # 07 Y:2010 | 07 | 2010 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $23,972 | $29,894 | Not Implemented |
OK0799 # 13 Y:2010 | 13 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,897 | $435 | Not Implemented |
OK0799 # 08 Y:2010 | 08 | 2010 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $12,490 | $8,730 | Not Implemented |
OK0799 # 10 Y:2010 | 10 | 2010 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $22,062 | $351,000 | Not Implemented |
OK0799 # 06 Y:2010 | 06 | 2010 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $31,971 | $54,000 | Not Implemented |
OK0799 # 11 Y:2010 | 11 | 2010 | INSULATE BARE EQUIPMENT | $1,902 | $1,801 | Not Implemented |
CO0642 # 02 Y:2010 | 02 | 2010 | USE SOLAR HEAT TO MAKE ELECTRICTY | $4,300 | $27,000 | Not Implemented |
CO0642 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,850 | $12,690 | Implemented |
CO0642 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $740 | $1,320 | Implemented |
CO0642 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,530 | $4,090 | Implemented |
CO0642 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,360 | $6,090 | Implemented |
UA0054 # 01 Y:2010 | 01 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $31,442 | $1,000 | Not Implemented |
UA0054 # 02 Y:2010 | 02 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,010 | $7,000 | Implemented |
UA0054 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $86,265 | $71,625 | Not Implemented |
UA0054 # 04 Y:2010 | 04 | 2010 | USE PHOTOCELL CONTROLS | $2,443 | $1,893 | Not Implemented |
UA0054 # 05 Y:2010 | 05 | 2010 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $42,638 | $40,400 | Not Implemented |
UA0054 # 06 Y:2010 | 06 | 2010 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $25,338 | $6,850 | Not Implemented |
UA0054 # 07 Y:2010 | 07 | 2010 | INSTALL TIMERS AND/OR THERMOSTATS | $4,372 | $3,230 | Implemented |