Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
52
matching recommendationsSIC | 353 | Construction And Related Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0110 # 02 Y:2013 | 02 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $6,320 | $260 | Implemented |
DL0110 # 01 Y:2013 | 01 | 2013 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $7,313 | $39,750 | Not Implemented |
DL0110 # 03 Y:2013 | 03 | 2013 | UPGRADE CONTROLS ON COMPRESSORS | $10,321 | $35,000 | Not Implemented |
DL0110 # 04 Y:2013 | 04 | 2013 | REDUCE VENTILATION AIR | $4,577 | $102 | Not Implemented |
DL0110 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,720 | $24,800 | Not Implemented |
DL0110 # 07 Y:2013 | 07 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,943 | $644 | Not Implemented |
DL0110 # 06 Y:2013 | 06 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,991 | $152 | Not Implemented |
IP0015 # 01 Y:2013 | 01 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,644 | $0 | Implemented |
IP0015 # 05 Y:2013 | 05 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $24,010 | $1,400 | Implemented |
IP0015 # 03 Y:2013 | 03 | 2013 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $730 | $0 | Not Implemented |
IP0015 # 04 Y:2013 | 04 | 2013 | INSTALL OCCUPANCY SENSORS | $1,044 | $118 | Not Implemented |
IP0015 # 02 Y:2013 | 02 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,757 | $0 | Not Implemented |
IP0015 # 09 Y:2013 | 09 | 2013 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,144 | $3,702 | Not Implemented |
IP0015 # 06 Y:2013 | 06 | 2013 | INSULATE BARE EQUIPMENT | $7,093 | $380 | Implemented |
IP0015 # 07 Y:2013 | 07 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,795 | $8,625 | Implemented |
IP0015 # 08 Y:2013 | 08 | 2013 | OPTIMIZE PLANT POWER FACTOR | $10,702 | $17,052 | Not Implemented |
OR0608 # 01 Y:2013 | 01 | 2013 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $32,340 | $0 | Implemented |
OR0608 # 02 Y:2013 | 02 | 2013 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $107,138 | $55,641 | Implemented |
OR0608 # 03 Y:2013 | 03 | 2013 | ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS | $125,546 | $300,000 | Not Implemented |
OR0608 # 04 Y:2013 | 04 | 2013 | ADJUST / MAINTAIN FORK LIFT TRUCKS FOR MOST EFFICIENT OPERATION | $11,970 | $41,000 | Not Implemented |
OR0608 # 05 Y:2013 | 05 | 2013 | INSULATE BARE EQUIPMENT | $518 | $135 | Not Implemented |
OR0608 # 06 Y:2013 | 06 | 2013 | INSTALL DESICCANT HUMIDITY CONTROL SYSTEM | $2,698 | $1,220 | Not Implemented |
OR0608 # 07 Y:2013 | 07 | 2013 | USE PHOTOCELL CONTROLS | $658 | $966 | Not Implemented |
BD0428 # 06 Y:2013 | 06 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,903 | $1,400 | Not Implemented |
BD0428 # 05 Y:2013 | 05 | 2013 | INSTALL OCCUPANCY SENSORS | $4,430 | $2,257 | Not Implemented |