IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

714

matching recommendations
Reset
SIC 3533 Oil And Gas Field Machinery
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LL0240 # 01 Y:2006 01 2006 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $40,093 $2,862 Implemented
LL0240 # 02 Y:2006 02 2006 USE PHOTOCELL CONTROLS $28,394 $1,110 Implemented
LL0240 # 03 Y:2006 03 2006 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $24,138 $143,240 Implemented
LL0240 # 04 Y:2006 04 2006 INSTALL TIMERS AND/OR THERMOSTATS $15,054 $726 Implemented
LL0240 # 05 Y:2006 05 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $11,827 $12,200 Implemented
LL0240 # 06 Y:2006 06 2006 INSTALL OCCUPANCY SENSORS $2,004 $990 Implemented
LL0240 # 07 Y:2006 07 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,657 $1,050 Implemented
LL0240 # 08 Y:2006 08 2006 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $421 $770 Not Implemented
LL0240 # 09 Y:2006 09 2006 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $21,764 $230 Implemented
TA0111 # 01 Y:2005 01 2005 CLEAR AND RENT EXISTING SPACE $225,000 $2,250 Not Implemented
TA0111 # 02 Y:2005 02 2005 AIR CONDITION ONLY SPACE NECESSARY $51,150 $0 Not Implemented
TA0111 # 03 Y:2005 03 2005 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $44,045 $20,000 Not Implemented
TA0111 # 04 Y:2005 04 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $17,913 $400 Not Implemented
TA0111 # 05 Y:2005 05 2005 OPTIMIZE PLANT POWER FACTOR $2,750 $5,500 Not Implemented
TA0111 # 06 Y:2005 06 2005 DISCONNECT BALLASTS $1,660 $140 Not Implemented
TA0111 # 07 Y:2005 07 2005 TURN OFF EQUIPMENT WHEN NOT IN USE $1,370 $10 Not Implemented
LL0224 # 01 Y:2005 01 2005 USE RADIANT HEATER FOR SPOT HEATING $4,838 $0 Not Implemented
LL0224 # 02 Y:2005 02 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,157 $0 Not Implemented
LL0224 # 03 Y:2005 03 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,031 $0 Not Implemented
LL0224 # 04 Y:2005 04 2005 USE PHOTOCELL CONTROLS $1,862 $0 Not Implemented
LL0224 # 05 Y:2005 05 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,687 $0 Not Implemented
LL0224 # 06 Y:2005 06 2005 INSTALL OCCUPANCY SENSORS $1,284 $0 Not Implemented
LL0224 # 07 Y:2005 07 2005 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,148 $0 Not Implemented
LL0224 # 08 Y:2005 08 2005 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $296 $0 Not Implemented
LL0219 # 01 Y:2005 01 2005 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT $49,904 $26,850 Implemented