Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

286

matching recommendations
Reset
SIC 3533 Oil And Gas Field Machinery
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0169 # 03 Y:1993 03 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $810 $2,000 Implemented
AM0169 # 04 Y:1993 04 1993 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $820 $1,700 Not Implemented
AM0169 # 05 Y:1993 05 1993 PAY UTILITY BILLS ON TIME $540 $0 Not Implemented
AM0110 # 01 Y:1991 01 1991 OPTIMIZE PLANT POWER FACTOR $1,260 $5,180 Not Implemented
AM0110 # 02 Y:1991 02 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $510 $750 Not Implemented
AM0110 # 03 Y:1991 03 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $131 $105 Not Implemented
AM0110 # 04 Y:1991 04 1991 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $315 $52 Not Implemented
AM0110 # 05 Y:1991 05 1991 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $240 $100 Not Implemented
AM0110 # 06 Y:1991 06 1991 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $200 $160 Not Implemented
AM0110 # 07 Y:1991 07 1991 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $85 $0 Not Implemented
AM0083 # 01 Y:1990 01 1990 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $10,970 $4,000 Implemented
AM0083 # 02 Y:1990 02 1990 ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE $13,250 $4,000 Implemented
AM0083 # 03 Y:1990 03 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,560 $7,000 Implemented
AM0083 # 04 Y:1990 04 1990 RECOVER WASTE HEAT FROM EQUIPMENT $2,230 $1,300 Not Implemented
AM0083 # 05 Y:1990 05 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,150 $2,220 Implemented
AM0083 # 06 Y:1990 06 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,300 $4,956 Not Implemented
AM0083 # 07 Y:1990 07 1990 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $1,330 $2,000 Implemented
AM0083 # 08 Y:1990 08 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $184 $76 Implemented
AM0083 # 09 Y:1990 09 1990 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $700 $200 Implemented
AM0072 # 01 Y:1989 01 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $45,100 $82,000 Not Implemented
AM0072 # 02 Y:1989 02 1989 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $13,470 $24,000 Not Implemented
AM0072 # 03 Y:1989 03 1989 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $9,950 $56,300 Not Implemented
AM0072 # 04 Y:1989 04 1989 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,400 $1,000 Implemented
AM0072 # 05 Y:1989 05 1989 PAY UTILITY BILLS ON TIME $3,941 $0 Implemented
AM0072 # 06 Y:1989 06 1989 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $2,900 $2,900 Implemented