Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
22
matching recommendationsSIC | 3537 | Industrial Trucks And Tractors |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0677 # 07 Y:2015 | 07 | 2015 | DISCONNECT BALLASTS | $654 | $79 | Implemented |
AM0677 # 06 Y:2015 | 06 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,433 | $469 | Implemented |
AM0677 # 05 Y:2015 | 05 | 2015 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $10,875 | $3,000 | Implemented |
AM0677 # 04 Y:2015 | 04 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,805 | $23 | Not Implemented |
AM0677 # 03 Y:2015 | 03 | 2015 | INSTALL OCCUPANCY SENSORS | $3,460 | $7,200 | Implemented |
AM0677 # 02 Y:2015 | 02 | 2015 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $22,000 | $1,140 | Implemented |
AM0677 # 01 Y:2015 | 01 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,570 | $130,700 | Implemented |
AM0120 # 05 Y:1991 | 05 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,050 | $1,960 | Not Implemented |
AM0120 # 08 Y:1991 | 08 | 1991 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $290 | $350 | Not Implemented |
AM0120 # 07 Y:1991 | 07 | 1991 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $640 | $50 | Not Implemented |
AM0120 # 06 Y:1991 | 06 | 1991 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $650 | $680 | Not Implemented |
AM0120 # 04 Y:1991 | 04 | 1991 | INSTALL SET-BACK TIMERS | $1,250 | $0 | Not Implemented |
AM0120 # 03 Y:1991 | 03 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,506 | $0 | Not Implemented |
AM0120 # 02 Y:1991 | 02 | 1991 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,950 | $215 | Not Implemented |
AM0120 # 01 Y:1991 | 01 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,000 | $0 | Not Implemented |
AM0082 # 01 Y:1990 | 01 | 1990 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $6,080 | $14,110 | Implemented |
AM0082 # 07 Y:1990 | 07 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $620 | $600 | Implemented |
AM0082 # 06 Y:1990 | 06 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $206 | $208 | Implemented |
AM0082 # 05 Y:1990 | 05 | 1990 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,380 | $0 | Implemented |
AM0082 # 04 Y:1990 | 04 | 1990 | RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS | $2,824 | $2,150 | Implemented |
AM0082 # 03 Y:1990 | 03 | 1990 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,730 | $12,000 | Not Implemented |
AM0082 # 02 Y:1990 | 02 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,360 | $2,000 | Implemented |