IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

18

matching recommendations
Reset
SIC 354 Metalworking Machinery
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LE0422 # 05 Y:2016 05 2016 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,151 $1,000 Implemented
LE0422 # 06 Y:2016 06 2016 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $1,304 $1,350 Implemented
LE0422 # 09 Y:2016 09 2016 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,319 $3,000 Implemented
WV0356 # 17 Y:2007 17 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $488 $40 Implemented
WV0356 # 15 Y:2007 15 2007 DEVELOP A REPAIR/REPLACE POLICY $504 $270 Implemented
WV0356 # 12 Y:2007 12 2007 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $697 $1,080 Implemented
WV0356 # 11 Y:2007 11 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $715 $350 Implemented
WV0356 # 10 Y:2007 10 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $855 $1,900 Implemented
WV0356 # 07 Y:2007 07 2007 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,349 $1,000 Implemented
WV0356 # 06 Y:2007 06 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,880 $0 Implemented
WV0356 # 03 Y:2007 03 2007 USE HEAT PUMP FOR SPACE CONDITIONING $5,326 $9,600 Implemented
LE0171 # 08 Y:2003 08 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $664 $100 Implemented
LE0171 # 05 Y:2003 05 2003 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,863 $608 Implemented
LE0171 # 03 Y:2003 03 2003 USE DEMAND CONTROLLER OR LOAD SHEDDER $3,645 $6,000 Implemented
LE0171 # 01 Y:2003 01 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $12,638 $0 Implemented
LE0147 # 04 Y:2002 04 2002 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,478 $750 Implemented
LE0147 # 02 Y:2002 02 2002 REPAIR OR REPLACE STEAM TRAPS $6,177 $4,200 Implemented
LE0147 # 01 Y:2002 01 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $11,429 $900 Implemented