Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
81
matching recommendationsSIC | 354 | Metalworking Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0202 # 08 Y:2016 | 08 | 2016 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,722 | $7,341 | Not Implemented |
MZ0202 # 07 Y:2016 | 07 | 2016 | CONDENSE OPERATION INTO ONE BUILDING | $7,503 | $0 | Not Implemented |
MZ0202 # 06 Y:2016 | 06 | 2016 | CONDENSE OPERATION INTO ONE BUILDING | $3,585 | $0 | Not Implemented |
MZ0202 # 01 Y:2016 | 01 | 2016 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $19,101 | $70,000 | Not Implemented |
MZ0202 # 02 Y:2016 | 02 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,180 | $27,600 | Not Implemented |
MZ0202 # 03 Y:2016 | 03 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $6,654 | $5,000 | Not Implemented |
MZ0202 # 04 Y:2016 | 04 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,839 | $3,225 | Not Implemented |
MZ0202 # 05 Y:2016 | 05 | 2016 | UPGRADE CONTROLS ON COMPRESSORS | $9,678 | $45,000 | Not Implemented |
MZ0142 # 01 Y:2014 | 01 | 2014 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $5,862 | $6,500 | Not Implemented |
MZ0142 # 02 Y:2014 | 02 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $505 | $1,000 | Not Implemented |
MZ0142 # 03 Y:2014 | 03 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,716 | $2,500 | Not Implemented |
MZ0142 # 04 Y:2014 | 04 | 2014 | INSULATE BARE EQUIPMENT | $206 | $720 | Not Implemented |
MZ0142 # 05 Y:2014 | 05 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,435 | $31,000 | Implemented |
MZ0142 # 06 Y:2014 | 06 | 2014 | USE PHOTOCELL CONTROLS | $1,432 | $980 | Not Implemented |
MZ0118 # 04 Y:2013 | 04 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,699 | $0 | Implemented |
MZ0118 # 06 Y:2013 | 06 | 2013 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,418 | $0 | Implemented |
MZ0118 # 07 Y:2013 | 07 | 2013 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,099 | $0 | Not Implemented |
MZ0118 # 10 Y:2013 | 10 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $21 | $60 | Implemented |
MZ0118 # 11 Y:2013 | 11 | 2013 | INSTALL DIRECT ACTING UNITS IN PLACE OF COMPRESSED AIR PRESSURE SYSTEM IN SAFETY SYSTEM | $702 | $9,752 | Implemented |
MZ0118 # 08 Y:2013 | 08 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $247 | $100 | Implemented |
MZ0118 # 09 Y:2013 | 09 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $50 | $0 | Implemented |
MZ0118 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,135 | $24,628 | Implemented |
MZ0118 # 05 Y:2013 | 05 | 2013 | USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER | $10,146 | $59,000 | Not Implemented |
MZ0118 # 03 Y:2013 | 03 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,880 | $950 | Implemented |
MZ0118 # 02 Y:2013 | 02 | 2013 | INSTALL OCCUPANCY SENSORS | $3,261 | $1,020 | Not Implemented |